Metraipolis › archive › dc_a310758de159
Beyond Kinematics: Benchmarking Simulation Fidelity for Muscle-Driven Imitation Learning — arXiv:2609.21909
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.21909
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-10T01:45:18.159Z
- SHA-256 of the archived text
3c142e152a8e037dbb025d00ba05cad02ac5356bd0696db047bca69b0e7538eb- Stable URL of this page
https://metraipolis.com/documento/dc_a310758de159
How to cite
Beyond Kinematics: Benchmarking Simulation Fidelity for Muscle-Driven Imitation Learning — arXiv:2609.21909 — arXiv (en), https://arxiv.org/abs/2609.21909 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a310758de159 (Metraipolis archive dc_a310758de159, sha256 3c142e152a8e037dbb025d00ba05cad02ac5356bd0696db047bca69b0e7538eb)
BibTeX
@misc{dca310758de159,
title = {Beyond Kinematics: Benchmarking Simulation Fidelity for Muscle-Driven Imitation Learning — arXiv:2609.21909},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.21909},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a310758de159; sha256 3c142e152a8e037dbb025d00ba05cad02ac5356bd0696db047bca69b0e7538eb},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.21909. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
In this work, we conduct a systematic comparison of two state-of-the-art motion-imitation reinforcement learning (MIRL) pipelines, one built on SCONE/HyFyDy and one built on MuJoCo/MyoSim. HyFyDy emphasizes physiological realism through detailed musculotendon modeling, while MuJoCo prioritizes computational efficiency and scalable policy learning. While recent work has demonstrated that both pipelines reproduce human kinematics with high fidelity, it remains unclear if they accurately capture the underlying neuromuscular behavior that produced the movement. This limitation is particularly important for robotic assistive-device design and control, where outcome measures such as muscle activation patterns and metabolic cost are often used as optimization targets. To conduct a systematic comparison, our work compares both pipelines using a common set of human motion-capture and electromyography (EMG) measurements. The results find that while both pipelines produce similar kinematics with relative accuracy, the muscle activations from HyFyDy are more aligned with the experimental EMG, as supported by the average pooled (RMSE, r) values for muscle activations from HyFyDy and MuJoCo: (0.164, 0.4) and (0.344, 0.11), respectively. While we conclude that the more advanced physiological realism of HyFyDy currently makes it more suitable for musculoskeletal modeling, both require further development to bring physiological realism to GPU-parallelizable simulation environments and advance robotic assistive device design. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-21 in cs.LG). Categorie arXiv: Machine Learning (cs.LG) ; Robotics (cs.RO). Pagina del lavoro: https://arxiv.org/abs/2609.21909 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-10T01:14:16.659Z dalla pagina https://arxiv.org/catchup/cs.LG/2026-09-21?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).