Metraipolis › archive › dc_a3016e777ff5

MedProb: Probing Internal Representations of Vision-Language Models for Medical Question Answering — arXiv:2609.04336

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.04336
License (as archived)
CC0-1.0
Archived
2026-10-16T22:31:24.285Z
SHA-256 of the archived text
ea72004637a1bb51f681b5a400bb5e5706dcc2729ebb40b0dfb55f5b13f7b3a7
Stable URL of this page
https://metraipolis.com/documento/dc_a3016e777ff5

How to cite

MedProb: Probing Internal Representations of Vision-Language Models for Medical Question Answering — arXiv:2609.04336 — arXiv (en), https://arxiv.org/abs/2609.04336 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a3016e777ff5 (Metraipolis archive dc_a3016e777ff5, sha256 ea72004637a1bb51f681b5a400bb5e5706dcc2729ebb40b0dfb55f5b13f7b3a7)
BibTeX
@misc{dca3016e777ff5,
  title = {MedProb: Probing Internal Representations of Vision-Language Models for Medical Question Answering — arXiv:2609.04336},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.04336},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a3016e777ff5; sha256 ea72004637a1bb51f681b5a400bb5e5706dcc2729ebb40b0dfb55f5b13f7b3a7},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.04336. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Medical visual question answering (Med-VQA) is often assumed to require medical fine-tuning, large models, or complex multi-agent pipelines. We revisit this assumption with \textbf{MedProb}, a lightweight probing framework that predicts multiple-choice Med-VQA answers from frozen VLM representations without free-text generation. Across PATH-VQA, SLAKE, and VQA-RAD, MedProb recovers substantially more answer-relevant signal than prompting and performs stronger than medical VLMs and agentic systems. Probing also reduces the apparent gap between small and large models compared to prompting, suggesting that smaller VLMs contain more recoverable Med-VQA signal than generation-based evaluation reveals. Across 14 matched general-purpose and medical VLM pairs, medical adaptation does not consistently improve this linear decodability. Finally, free-text generation exhibits an answer-position bias of up to 10 percentage points, whereas MedProb also has positional bias, however, it is impacted differently than prompting. Our main results target the multiple-choice/multiclass Med-VQA setting; we additionally show the probe can be extended to open-ended generation via a rejection-sampling scoring procedure.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-07 in cs.CL).
Categorie arXiv: Computation and Language (cs.CL).
Pagina del lavoro: https://arxiv.org/abs/2609.04336 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T22:21:16.258Z dalla pagina https://arxiv.org/catchup/cs.CL/2026-09-07?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).