Metraipolis › archive › dc_a293bd814db1
Cross-Anatomy Transfer Versus Sparse Interpolation in Digital-Twin-Oriented Aortic Fluid-Structure Interaction Surrogates — arXiv:2609.16322
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.16322
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-15T18:32:04.069Z
- SHA-256 of the archived text
8ebc7db13011b478ec1f4bc7d52c56a6602d32e0c1f5c93499328e35442b5fbd- Stable URL of this page
https://metraipolis.com/documento/dc_a293bd814db1
How to cite
Cross-Anatomy Transfer Versus Sparse Interpolation in Digital-Twin-Oriented Aortic Fluid-Structure Interaction Surrogates — arXiv:2609.16322 — arXiv (en), https://arxiv.org/abs/2609.16322 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a293bd814db1 (Metraipolis archive dc_a293bd814db1, sha256 8ebc7db13011b478ec1f4bc7d52c56a6602d32e0c1f5c93499328e35442b5fbd)
BibTeX
@misc{dca293bd814db1,
title = {Cross-Anatomy Transfer Versus Sparse Interpolation in Digital-Twin-Oriented Aortic Fluid-Structure Interaction Surrogates — arXiv:2609.16322},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.16322},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a293bd814db1; sha256 8ebc7db13011b478ec1f4bc7d52c56a6602d32e0c1f5c93499328e35442b5fbd},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.16322. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Surrogate credibility for fluid-structure interac- tion (FSI) requires distinguishing transfer across independent anatomies from interpolation within an already sampled surface. Four de-identified human aortic models from the Vascular Model Repository were reconstructed into separate lumen and nominal 1.5-mm wall domains and analyzed under matched first-cycle two-way FSI. A geometry-only LightGBM prior, selected by leave-one-anatomy-out development on three anatomies, was zero-shot evaluated on a fourth, then probed with a post-zero- shot sparse field-completion case study over six targets. Zero-shot transfer was poor across all targets. At a five-percent anchor level (203 anchors, 3,852 evaluation nodes), prior-plus-adaptation reached an oscillatory shear index (OSI) R2 of 0.603. However, same-anchor controls tuned only on the three development anatomies were stronger for several outcomes: inverse-distance weighting reached R2 = 0.829 (OSI), 0.617 (peak von Mises stress), 0.676 (mean stress); radial basis function interpolation reached 0.917, 0.714, 0.778. Sparse within-anatomy labels thus support field completion, but this four-anatomy cohort gives no evidence the cross-anatomy prior adds value beyond direct interpolation. We frame this as a first computational stage toward a measurement-linked digital twin: the surrogate/update layer is evaluated here, while larger cohorts, converged FSI, measurable patient-side inputs, and physics-informed learning remain future work, not a claim of a complete clinical twin. Our code, data and computation files are available at https://github. com/ali-nourbakhsh2005/Aortic-FSI-Sparse-Field-Completion Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-16 in cs.AI). Categorie arXiv: Artificial Intelligence (cs.AI) ; Machine Learning (cs.LG). Pagina del lavoro: https://arxiv.org/abs/2609.16322 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-15T18:03:09.431Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-16?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).