Metraipolis › archive › dc_a248677b8dbf

ProtoCAM: Interpretable Few-Shot Mask-Guided Prototypical Learning for Breast Lesion Classification in Ultrasound Imaging — arXiv:2609.13340

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.13340
License (as archived)
CC0-1.0
Archived
2026-10-15T22:48:25.537Z
SHA-256 of the archived text
75179badeed98a2255a2f127c868839b3fdf70f61afccb2702cbdff972fd7822
Stable URL of this page
https://metraipolis.com/documento/dc_a248677b8dbf

How to cite

ProtoCAM: Interpretable Few-Shot Mask-Guided Prototypical Learning for Breast Lesion Classification in Ultrasound Imaging — arXiv:2609.13340 — arXiv (en), https://arxiv.org/abs/2609.13340 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a248677b8dbf (Metraipolis archive dc_a248677b8dbf, sha256 75179badeed98a2255a2f127c868839b3fdf70f61afccb2702cbdff972fd7822)
BibTeX
@misc{dca248677b8dbf,
  title = {ProtoCAM: Interpretable Few-Shot Mask-Guided Prototypical Learning for Breast Lesion Classification in Ultrasound Imaging — arXiv:2609.13340},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.13340},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a248677b8dbf; sha256 75179badeed98a2255a2f127c868839b3fdf70f61afccb2702cbdff972fd7822},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.13340. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Breast ultrasound imaging plays an important role in the early detection and diagnosis of breast cancer, particularly for patients with dense breast tissue. However, developing reliable deep learning models for ultrasound analysis is challenging due to limited annotated medical data and the need for interpretable predictions. To address these challenges, this paper proposes ProtoCAM, an explainable few-shot learning framework for breast lesion classification that integrates mask-guided feature encoding, prototypical metric learning, and gradient-based visual explanations. The proposed approach leverages lesion masks to guide feature extraction and constructs class prototypes within an embedding space to enable robust classification under limited training samples. The framework was evaluated on the BUSI dataset using a stratified group k-fold cross-validation protocol to prevent patient-level data leakage. Experimental results demonstrate ProtoCAM's high performance in low-data scenarios. In a 3-way 5-shot setting, the proposed method achieves a macro F1-score of 0.910, representing a substantial improvement over standard supervised CNN models. Among the evaluated backbone networks, ResNet18 achieved the best performance, reaching a macro F1-score of 91.65% under a 15-shot configuration, providing interpretable insights into the classification decisions. These results highlight the potential of explainable few-shot learning frameworks for reliable computer-aided breast cancer diagnosis in data-scarce medical imaging environments.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-15 in cs.AI).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2609.13340 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-15T22:29:03.463Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-15?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).