Metraipolis › archive › dc_a1b448f09041

Coordinated Primary Frequency Regulation and Grid-Forming Control for Wind Turbine Generators — arXiv:2608.02813

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.02813
License (as archived)
CC0-1.0
Archived
2026-10-31T13:27:34.052Z
SHA-256 of the archived text
7e99b956562ea187ba803b7aaee7140ccdfbdbec1b15e73307e8a7b68d3ba8b8
Stable URL of this page
https://metraipolis.com/documento/dc_a1b448f09041

How to cite

Coordinated Primary Frequency Regulation and Grid-Forming Control for Wind Turbine Generators — arXiv:2608.02813 — arXiv (en), https://arxiv.org/abs/2608.02813 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a1b448f09041 (Metraipolis archive dc_a1b448f09041, sha256 7e99b956562ea187ba803b7aaee7140ccdfbdbec1b15e73307e8a7b68d3ba8b8)
BibTeX
@misc{dca1b448f09041,
  title = {Coordinated Primary Frequency Regulation and Grid-Forming Control for Wind Turbine Generators — arXiv:2608.02813},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.02813},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a1b448f09041; sha256 7e99b956562ea187ba803b7aaee7140ccdfbdbec1b15e73307e8a7b68d3ba8b8},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.02813. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Conventional grid-forming (GFM) control strategies often treat the DC source as an unconstrained link, creating mismatches when applied to the wind turbine generators (WTGs). Focusing on primary frequency regulation, this paper systematically investigates the mismatch between the GFM-WTGs behavior and the droop-based primary frequency regulation. To address this issue, a novel coordination strategy between WTG primary frequency regulation and GFM control is proposed. By establishing well-designed relationships among the power-tracking coefficient, power set-point, and frequency deviation, the proposed strategy enables GFM-WTGs to participate consistently in primary frequency regulation within predefined frequency limits while maintaining appropriate power points and effectively utilizing the allowable power reserve. Furthermore, the proposed method preserves the control structure and dynamic performance of conventional GFM control and inherently adapts to varying wind-speed conditions. Comparative case studies under different operating scenarios demonstrate the effectiveness and superiority of the proposed strategy.

Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-08-05 in eess.SY).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2608.02813 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-31T13:14:59.729Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-08-05?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).