Metraipolis › archive › dc_a13738fa4d03
Intrinsic Vectorial Gradiometry via Quantum Control of a Spin-based Sensor — arXiv:2609.21776
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.21776
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-10T02:52:31.302Z
- SHA-256 of the archived text
617d48696902c83276434aa888c5b48ea2abcb9202c103656603eba0472e5504- Stable URL of this page
https://metraipolis.com/documento/dc_a13738fa4d03
How to cite
Intrinsic Vectorial Gradiometry via Quantum Control of a Spin-based Sensor — arXiv:2609.21776 — arXiv (en), https://arxiv.org/abs/2609.21776 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a13738fa4d03 (Metraipolis archive dc_a13738fa4d03, sha256 617d48696902c83276434aa888c5b48ea2abcb9202c103656603eba0472e5504)
BibTeX
@misc{dca13738fa4d03,
title = {Intrinsic Vectorial Gradiometry via Quantum Control of a Spin-based Sensor — arXiv:2609.21776},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.21776},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a13738fa4d03; sha256 617d48696902c83276434aa888c5b48ea2abcb9202c103656603eba0472e5504},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.21776. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Gradiometry provides a versatile alternative to passive environmental shielding in quasi-static magnetometry, effectively suppressing background noise through differential signal extraction. Nevertheless, traditional implementations rely on multi-sensor architectures restricted to spatial gradients, where subtracting signals from independent detectors involves imperfect suppression of common-mode noise and artifacts, limiting their sensitivity. To overcome these limitations, we introduce a quantum control sequence that enables intrinsic temporal and spatial vectorial gradiometry of magnetic fields using a single quantum sensor. Our method provides direct access to first and higher-order derivatives of the magnetic field and extended applicability via auxiliary nuclear spin memory. We showcase this protocol on an ensemble of nitrogen-vacancy (NV) centers in diamond and combine it with mechanical control to realize high-precision differential sensing. Through detailed numerical simulations, we demonstrate the performance of our scheme in two critical DC magnetometry applications: (i) vector magnetic anomaly detection and (ii) non-invasive gradiometry of neuronal action potentials. Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-09-21 in quant-ph). Categorie arXiv: Quantum Physics (quant-ph). Pagina del lavoro: https://arxiv.org/abs/2609.21776 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-10T02:31:30.455Z dalla pagina https://arxiv.org/catchup/quant-ph/2026-09-21?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).