Metraipolis › archive › dc_a132886bf055
Towards a barrier-free anthropomorphic brain phantom for quantitative magnetic resonance imaging: Design, first construction attempt, and challenges — Europe PMC PMID:37437022
- Source
- Europe PMC (en)
- Original
- https://europepmc.org/article/MED/37437022
- DOI
- 10.1371/journal.pone.0285432
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-07T12:57:57.502Z
- SHA-256 of the archived text
b853003364c79bdd456c05442bff2eeb233f38e5c7408d9b50eb684c1283f921- Stable URL of this page
https://metraipolis.com/documento/dc_a132886bf055
How to cite
Towards a barrier-free anthropomorphic brain phantom for quantitative magnetic resonance imaging: Design, first construction attempt, and challenges — Europe PMC PMID:37437022 — Europe PMC (en), https://europepmc.org/article/MED/37437022 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a132886bf055 (Metraipolis archive dc_a132886bf055, sha256 b853003364c79bdd456c05442bff2eeb233f38e5c7408d9b50eb684c1283f921)
BibTeX
@misc{dca132886bf055,
title = {Towards a barrier-free anthropomorphic brain phantom for quantitative magnetic resonance imaging: Design, first construction attempt, and challenges — Europe PMC PMID:37437022},
howpublished = {Europe PMC (en)},
url = {https://europepmc.org/article/MED/37437022},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a132886bf055; sha256 b853003364c79bdd456c05442bff2eeb233f38e5c7408d9b50eb684c1283f921},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/37437022. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Existing magnetic resonance imaging (MRI) reference objects, or phantoms, are typically constructed from simple liquid or gel solutions in containers with specific geometric configurations to enable multi-year stability. However, there is a need for phantoms that better mimic the human anatomy without barriers between the tissues. Barriers result in regions without MRI signal between the different tissue mimics, which is an artificial image artifact. We created an anatomically representative 3D structure of the brain that mimicked the T1 and T2 relaxation properties of white and gray matter at 3 T. While the goal was to avoid barriers between tissues, the 3D printed barrier between white and gray matter and other flaws in the construction were visible at 3 T. Stability measurements were made using a portable MRI system operating at 64 mT, and T2 relaxation time was stable from 0 to 22 weeks. The phantom T1 relaxation properties did change from 0 to 10 weeks; however, they did not substantially change between 10 weeks and 22 weeks. The anthropomorphic phantom used a dissolvable mold construction method to better mimic anatomy, which worked in small test objects. The construction process, though, had many challenges. We share this work with the hope that the community can build on our experience. Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera). Pubblicazione: PloS one, 2023 (prima pubblicazione 2023-07-12). Identificativi: PMID 37437022 · PMCID PMC10337967 · DOI 10.1371/journal.pone.0285432. Descrittori MeSH principali: Brain; Magnetic Resonance Imaging. Pagina: https://europepmc.org/article/MED/37437022 — https://doi.org/10.1371/journal.pone.0285432. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0. Letto il 2026-10-07T12:28:09.605Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.