Metraipolis › archive › dc_a0f7aa8306fa
A 2D Image Feedback-Based Autonomous Endovascular Navigation Method: A Perception and Control Framework — arXiv:2610.21481
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.21481
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T10:39:56.341Z
- SHA-256 of the archived text
def5af9287560f312e0b0cfe9fa223b520d80eebd6987d9ee4df2c7ab70312ef- Stable URL of this page
https://metraipolis.com/documento/dc_a0f7aa8306fa
How to cite
A 2D Image Feedback-Based Autonomous Endovascular Navigation Method: A Perception and Control Framework — arXiv:2610.21481 — arXiv (en), https://arxiv.org/abs/2610.21481 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_a0f7aa8306fa (Metraipolis archive dc_a0f7aa8306fa, sha256 def5af9287560f312e0b0cfe9fa223b520d80eebd6987d9ee4df2c7ab70312ef)
BibTeX
@misc{dca0f7aa8306fa,
title = {A 2D Image Feedback-Based Autonomous Endovascular Navigation Method: A Perception and Control Framework — arXiv:2610.21481},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.21481},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_a0f7aa8306fa; sha256 def5af9287560f312e0b0cfe9fa223b520d80eebd6987d9ee4df2c7ab70312ef},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.21481. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
In endovascular interventions, physicians rely on planar DSA and X-ray fluoroscopy to interpret vessel anatomy and device motion, yet converting these images into feedback for autonomous navigation remains difficult. A perception and control method is formulated for two-dimensional image feedback. Vessel masks are converted into a labeled centerline graph, and device-tip estimates are projected onto a planned path to obtain progress, deviation, and direction. A rule-based controller uses these quantities for delivery, branch selection, probing, rollback, and recovery. The method was evaluated on a physical dual-device robotic platform in 65 closed-loop runs using simulator-rendered planar images across three paths. All runs reached at least 0.95 maximum observed guidewire progress; two runs (3.1%) met the prespecified failure rule of three or more autonomous stop events. The results establish route-level performance on the tested platform; clinical image sequences and broader anatomy remain to be evaluated. Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.RO, nuovi lavori del giorno). Categorie arXiv: Robotics (cs.RO). Pagina del lavoro: https://arxiv.org/abs/2610.21481 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T08:52:17.643Z dalla pagina https://arxiv.org/list/cs.RO/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).