Metraipolis › archive › dc_9f403ecc9ee6

CARDEA: Auditable Reasoning Grounded in Spatial Evidence for End-to-End Coronary Angiography Interpretation — arXiv:2609.06931

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.06931
License (as archived)
CC0-1.0
Archived
2026-10-16T15:09:28.467Z
SHA-256 of the archived text
d9a9af8d0fe9bf15329b838464f63f92f0c33fd718758594d3b6b46b74a3a87d
Stable URL of this page
https://metraipolis.com/documento/dc_9f403ecc9ee6

How to cite

CARDEA: Auditable Reasoning Grounded in Spatial Evidence for End-to-End Coronary Angiography Interpretation — arXiv:2609.06931 — arXiv (en), https://arxiv.org/abs/2609.06931 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_9f403ecc9ee6 (Metraipolis archive dc_9f403ecc9ee6, sha256 d9a9af8d0fe9bf15329b838464f63f92f0c33fd718758594d3b6b46b74a3a87d)
BibTeX
@misc{dc9f403ecc9ee6,
  title = {CARDEA: Auditable Reasoning Grounded in Spatial Evidence for End-to-End Coronary Angiography Interpretation — arXiv:2609.06931},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.06931},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_9f403ecc9ee6; sha256 d9a9af8d0fe9bf15329b838464f63f92f0c33fd718758594d3b6b46b74a3a87d},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.06931. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Invasive coronary angiography (CAG) is the gold standard for diagnosing coronary artery disease, but interpretation varies substantially among observers. Existing AI systems can improve consistency but lack auditable decision processes and are limited in comprehensive open-ended assessment, undermining clinician trust and clinical adoption readiness. We developed CARDEA, a unified large vision-language model that serves as the inference core of a CAG pipeline. It was trained solely on public datasets and closed-ended tasks in three stages: visual feature alignment, a self-distilled Chain-of-Box (CoB) cold start, and reinforcement learning with verifiable rewards (RLVR) with a CoB reward encouraging bounding-box use in the reasoning trace. We assessed its two study-level diagnoses, dominance classification and complexity assessment, against a dedicated classifier and two interventional cardiologists. Report generation was excluded from training and evaluated zero-shot across stages on an external cohort using vessel-severity macro-$F_1$. CARDEA trailed the classifier on in-distribution dominance but drew level under domain shift (accuracy, 0.91 [95% confidence interval (CI), 0.86 to 0.95]) and was comparable to the cardiologists on complexity assessment (accuracy, 0.90 [CI, 0.82 to 0.97]). Only RLVR improved zero-shot report generation, raising its vessel-severity macro-$F_1$ (0.686 [CI, 0.664 to 0.707]) above the untuned base model (0.513) and over twice the always-normal floor (0.312). CARDEA runs an end-to-end CAG pipeline from raw multi-view videos through keyframe selection to study-level diagnosis while exposing auditable spatial evidence behind its conclusions. RLVR on verifiable closed-ended tasks surfaced open-ended reporting ability that supervised imitation did not. Clinical use requires prospective validation against expert cardiologists.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-09 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2609.06931 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T14:49:57.148Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-09?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).