Cerebral phosphoester signals measured by 31P magnetic resonance spectroscopy at 3 and 7 Tesla — Europe PMC PMID:33735267
- Source
- Europe PMC (en)
- Original
- https://europepmc.org/article/MED/33735267
- DOI
- 10.1371/journal.pone.0248632
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-05T13:28:22.378Z
- SHA-256 of the archived text
05930e4196a59912ff1604e003f12729d107bbe8db764c4b2d1930f409b965fb- Stable URL of this page
https://metraipolis.com/documento/dc_9f0773b5cd88
How to cite
Cerebral phosphoester signals measured by 31P magnetic resonance spectroscopy at 3 and 7 Tesla — Europe PMC PMID:33735267 — Europe PMC (en), https://europepmc.org/article/MED/33735267 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_9f0773b5cd88 (Metraipolis archive dc_9f0773b5cd88, sha256 05930e4196a59912ff1604e003f12729d107bbe8db764c4b2d1930f409b965fb)
BibTeX
@misc{dc9f0773b5cd88,
title = {Cerebral phosphoester signals measured by 31P magnetic resonance spectroscopy at 3 and 7 Tesla — Europe PMC PMID:33735267},
howpublished = {Europe PMC (en)},
url = {https://europepmc.org/article/MED/33735267},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_9f0773b5cd88; sha256 05930e4196a59912ff1604e003f12729d107bbe8db764c4b2d1930f409b965fb},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/33735267. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Abnormal cell membrane metabolism is associated with many neuropsychiatric disorders. Free phosphomonoesters and phosphodiesters, which can be detected by in vivo 31P magnetic resonance spectroscopy (MRS), are important cell membrane building blocks. However, the quantification of phosphoesters has been highly controversial even in healthy individuals due to overlapping signals from macromolecule membrane phospholipids (MP). In this study, high signal-to-noise ratio (SNR) cerebral 31P MRS spectra were acquired from healthy volunteers at both 3 and 7 Tesla. Our results indicated that, with minimal spectral interference from MP, the [phosphocreatine (PCr)]/[phosphocholine (PC) + glycerophosphocholine (GPC)] ratio measured at 7 Tesla agreed with its value expected from biochemical constraints. In contrast, the 3 Tesla [PCr]/[PC+GPC] ratio obtained using standard spectral fitting procedures was markedly smaller than the 7 Tesla ratio and than the expected value. The analysis suggests that the commonly used spectral model for MP may fail to capture its complex spectral features at 3 Tesla, and that additional prior knowledge is necessary to reliably quantify the phosphoester signals at low magnetic field strengths when spectral overlapping is significant. Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera). Pubblicazione: PloS one, 2021 (prima pubblicazione 2021-03-18). Identificativi: PMID 33735267 · PMCID PMC7971532 · DOI 10.1371/journal.pone.0248632. Pagina: https://europepmc.org/article/MED/33735267 — https://doi.org/10.1371/journal.pone.0248632. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0. Letto il 2026-11-05T13:18:53.886Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.