Metraipolis › archive › dc_9e33abb031a6
Gaze responses to false-positive computer-aided detection prompts during colonoscopy: a paired-video and real-time eye-tracking study — arXiv:2609.25581
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.25581
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T13:45:07.815Z
- SHA-256 of the archived text
dbf091c06f80b0180c709def5c26e7939fc7e1aaf8355edcb95b108eac120748- Stable URL of this page
https://metraipolis.com/documento/dc_9e33abb031a6
How to cite
Gaze responses to false-positive computer-aided detection prompts during colonoscopy: a paired-video and real-time eye-tracking study — arXiv:2609.25581 — arXiv (en), https://arxiv.org/abs/2609.25581 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_9e33abb031a6 (Metraipolis archive dc_9e33abb031a6, sha256 dbf091c06f80b0180c709def5c26e7939fc7e1aaf8355edcb95b108eac120748)
BibTeX
@misc{dc9e33abb031a6,
title = {Gaze responses to false-positive computer-aided detection prompts during colonoscopy: a paired-video and real-time eye-tracking study — arXiv:2609.25581},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.25581},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_9e33abb031a6; sha256 dbf091c06f80b0180c709def5c26e7939fc7e1aaf8355edcb95b108eac120748},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.25581. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
False-positive computer-aided detection (CADe) prompts may divert endoscopists' attention during colonoscopy, yet the attentional impact of individual prompts remains unclear. We used event-locked eye tracking to quantify gaze attraction and attention occupation in complementary retrospective and prospective studies. In a retrospective paired-video experiment, 3 senior and 2 novice endoscopists viewed 60 colonoscopy videos with and without CADe. The prospective study recorded gaze during 42 real-time CADe-assisted colonoscopies performed by 9 senior endoscopists. Screened CADe prompts outside expert-annotated lesion windows were classified as false-positive artifact events. False-positive prompts attracted gaze in 48.6% (68/140) of retrospective observations and 65.2% (533/817) of prospective events. Among attraction events with complete recovery, median attention occupation lasted 1000 ms in the retrospective study and 1100 ms in the prospective study. Corresponding median prompt durations were 33 ms and 267 ms, with median time amplifications of 17.55-fold and 5.15-fold, respectively. In paired retrospective comparisons, visible artifact prompts drew gaze closer to the prompted region than did the same-coordinate unassisted reference. Secondary retrospective analyses showed high lesion gaze recognition without and with CADe (98.0% versus 99.0%). First gaze entry into lesion regions occurred 147.8 ms earlier with CADe. Across controlled and real-time clinical settings, false-positive CADe prompts frequently captured gaze, with attention persisting beyond prompt visibility. These findings support considering prompt-related attentional burden in CADe evaluation and design. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-23 in cs.AI). Categorie arXiv: Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2609.25581 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-08T13:18:38.096Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-23?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).