Metraipolis › archive › dc_9dfec7c78a97
T2 estimation from MOLLI acquisitions — arXiv:2609.19987
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.19987
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-10T06:15:42.070Z
- SHA-256 of the archived text
871e6c909fdb025730b1e9127a034d41b3622b4230345064b2c4f22c5e82c762- Stable URL of this page
https://metraipolis.com/documento/dc_9dfec7c78a97
How to cite
T2 estimation from MOLLI acquisitions — arXiv:2609.19987 — arXiv (en), https://arxiv.org/abs/2609.19987 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_9dfec7c78a97 (Metraipolis archive dc_9dfec7c78a97, sha256 871e6c909fdb025730b1e9127a034d41b3622b4230345064b2c4f22c5e82c762)
BibTeX
@misc{dc9dfec7c78a97,
title = {T2 estimation from MOLLI acquisitions — arXiv:2609.19987},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.19987},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_9dfec7c78a97; sha256 871e6c909fdb025730b1e9127a034d41b3622b4230345064b2c4f22c5e82c762},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.19987. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Cardiac T1 and T2 quantitative magnetic resonance imaging (MRI) is a technique that provides characterization of a multitude of myocardial pathologies. However, each parameter requires its own specialized acquisition sequence, which may be time-consuming. In this work, we demonstrate that MOLLI, an acquisition sequence commonly used to perform T1 mapping, is also sensitive to T2, and can also be used for myocardial T2 mapping. Although MOLLI is not designed for T2 mapping, its signal evolution inherently depends on both T1 and T2 relaxation. Here, we demonstrate that this dependence is sufficiently strong to allow T2 estimation directly from MOLLI T1-weighted images, using appropriate signal modelling. This finding opens the possibility of obtaining simultaneously T1 and T2 maps from a single MOLLI acquisition, reducing total scan time and potentially improving patient comfort and clinical throughput. Tema degli esploratori: scienze della vita e salute (retro-catalogo arXiv: annunci del 2026-09-18 in q-bio.QM). Categorie arXiv: Medical Physics (physics.med-ph) ; Quantitative Methods (q-bio.QM). Pagina del lavoro: https://arxiv.org/abs/2609.19987 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-10T05:51:30.376Z dalla pagina https://arxiv.org/catchup/q-bio.QM/2026-09-18?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).