Metraipolis › archive › dc_9d3255957bd0

Automated Screw Planning for Reduced Pelvic Fractures Based on Statistical Shape Models and Deep Learning — arXiv:2609.36847

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.36847
License (as archived)
CC0-1.0
Archived
2026-10-07T16:23:08.628Z
SHA-256 of the archived text
f27eee6460192941106ae82523924bde6cac15c63cc96b41b98a17e19d62c71d
Stable URL of this page
https://metraipolis.com/documento/dc_9d3255957bd0

How to cite

Automated Screw Planning for Reduced Pelvic Fractures Based on Statistical Shape Models and Deep Learning — arXiv:2609.36847 — arXiv (en), https://arxiv.org/abs/2609.36847 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_9d3255957bd0 (Metraipolis archive dc_9d3255957bd0, sha256 f27eee6460192941106ae82523924bde6cac15c63cc96b41b98a17e19d62c71d)
BibTeX
@misc{dc9d3255957bd0,
  title = {Automated Screw Planning for Reduced Pelvic Fractures Based on Statistical Shape Models and Deep Learning — arXiv:2609.36847},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.36847},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_9d3255957bd0; sha256 f27eee6460192941106ae82523924bde6cac15c63cc96b41b98a17e19d62c71d},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.36847. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Percutaneous iliosacral screw fixation is an important minimally invasive treatment for unstable pelvic fractures. Because the sacroiliac region has complex anatomy and narrow screw corridors, the accuracy and safety of screw placement directly affect surgical outcomes. Accurate and reliable preoperative screw planning is therefore essential to improve surgical success and reduce intraoperative risks. Conventional preoperative planning typically requires surgeons to determine screw trajectories through manual measurements, a labor-intensive process that depends on subjective clinical experience. To address these challenges, we propose a fully automated pipeline for preoperative iliosacral screw planning in patients with pelvic fractures. Using patient-specific three-dimensional anatomy, the pipeline automatically identifies safe screw corridors and generates individualized insertion trajectories to support clinical preoperative planning. We evaluated the proposed pipeline on 200 clinical cases of pelvic fractures. Compared with conventional manual measurements, the safety margin of the safe insertion corridors increased by 2% across the four screw types, the mean planning time decreased by more than 90%, and the clinical acceptance rate reached 95%.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-30 in cs.AI).
Categorie arXiv: Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2609.36847 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T15:54:53.553Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-30?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).