Metraipolis › archive › dc_9ceef1eb929e
DeBoneDiT: Depth-Driven Conditional Bridge Diffusion Transformers for Bone Suppression in Chest X-Ray Images — arXiv:2610.19466
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.19466
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-15T21:55:59.586Z
- SHA-256 of the archived text
e03c63b89b93edffc79c2ebe5c1ea2f70b2c3b3b44dc18caabf02e96937f6b58- Stable URL of this page
https://metraipolis.com/documento/dc_9ceef1eb929e
How to cite
DeBoneDiT: Depth-Driven Conditional Bridge Diffusion Transformers for Bone Suppression in Chest X-Ray Images — arXiv:2610.19466 — arXiv (en), https://arxiv.org/abs/2610.19466 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_9ceef1eb929e (Metraipolis archive dc_9ceef1eb929e, sha256 e03c63b89b93edffc79c2ebe5c1ea2f70b2c3b3b44dc18caabf02e96937f6b58)
BibTeX
@misc{dc9ceef1eb929e,
title = {DeBoneDiT: Depth-Driven Conditional Bridge Diffusion Transformers for Bone Suppression in Chest X-Ray Images — arXiv:2610.19466},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.19466},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_9ceef1eb929e; sha256 e03c63b89b93edffc79c2ebe5c1ea2f70b2c3b3b44dc18caabf02e96937f6b58},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.19466. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Chest X-Ray (CXR) is a primary modality for diagnosing pulmonary diseases, yet the overlap of bony structures often obscures critical radiographic findings, increasing the risk of diagnostic uncertainty. While Dual-Energy Subtraction (DES) is the clinical benchmark for bone suppression, its widespread adoption is primarily hindered by specialized hardware requirements and increased radiation exposure. Recently, diffusion-based generative models have shown promise for this task, yet they are still constrained by reconstruction-biased latent compression, prior-induced domain gap, and a scarcity of high-quality paired datasets. To address these challenges, we propose DeBoneDiT, a depth-driven conditional bridge diffusion Transformer architecture for efficient high-resolution bone suppression. We first introduce Depth Auto-Encoder (DAE), a structure-aware vision tokenizer for latent compression. By incorporating a multi-level depth feature loss derived from the pretrained Depth Anything V2 encoder, DAE preserves both visual fidelity and structural consistency. Second, we formulate bone suppression as a source-conditioned Brownian bridge diffusion process, leveraging CXRs as both the diffusion prior and structural guidance to narrow the source-to-target domain gap and maintain anatomical plausibility. Furthermore, we have constructed and released SZCH-X-Rays, the largest publicly available high-quality paired dataset for bone suppression to date, comprising 741 pairs of CXR and DES soft tissue images. Extensive experiments and downstream evaluation demonstrate that DeBoneDiT achieves superior bone suppression performance with reduced computational overhead. Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2610.19466 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-15T21:38:29.462Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).