Metraipolis › archive › dc_9bf36a43ccd0

Design of a Fully Actuated 4-DOF Robotic Finger With Joint-Specific Hybrid Remote Actuation — arXiv:2610.10180

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.10180
License (as archived)
CC0-1.0
Archived
2026-10-08T12:49:21.620Z
SHA-256 of the archived text
2c6ccb87e6673bc41e4b3317eac2c020d032d6d1e4d82a89796b759a6ccf49de
Stable URL of this page
https://metraipolis.com/documento/dc_9bf36a43ccd0

How to cite

Design of a Fully Actuated 4-DOF Robotic Finger With Joint-Specific Hybrid Remote Actuation — arXiv:2610.10180 — arXiv (en), https://arxiv.org/abs/2610.10180 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_9bf36a43ccd0 (Metraipolis archive dc_9bf36a43ccd0, sha256 2c6ccb87e6673bc41e4b3317eac2c020d032d6d1e4d82a89796b759a6ccf49de)
BibTeX
@misc{dc9bf36a43ccd0,
  title = {Design of a Fully Actuated 4-DOF Robotic Finger With Joint-Specific Hybrid Remote Actuation — arXiv:2610.10180},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.10180},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_9bf36a43ccd0; sha256 2c6ccb87e6673bc41e4b3317eac2c020d032d6d1e4d82a89796b759a6ccf49de},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.10180. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

This paper presents a fully actuated 4-DOF robotic finger using a joint-specific hybrid remote-actuation architecture. The metacarpophalangeal (MCP) joint is driven by two coordinated rigid-link transmission sets, whereas the proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints are independently actuated by closed-loop wire transmissions incorporating circular rolling-contact joints (RCJs). A larger transmission radius is used at the PIP joint than at the DIP joint. The RCJ wire geometry maintains the total wire-loop length during joint rotation, and the DIP wire routing is designed so that PIP motion does not affect its differential actuation for a fixed MCP configuration. The distal wire transmission, MCP linkage, and fingertip kinematics are analytically modeled. In experiments, the transmission behavior was quantitatively evaluated from the ball-screw displacements measured using ArUco-marker tracking. MCP actuation produced measurable displacements of the PIP and DIP transmission units, whereas isolated PIP and DIP actuation with the MCP fixed supported the intended mechanical decoupling between the distal transmissions. The mean peak fingertip forces under isolated MCP, PIP, and DIP actuation were 21.28 N, 9.22 N, and 5.75 N, respectively. The resulting finger postures were also examined using objects of different geometries and sizes.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.RO, nuovi lavori del giorno).
Categorie arXiv: Robotics (cs.RO).
Pagina del lavoro: https://arxiv.org/abs/2610.10180 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-08T12:18:30.572Z dalla pagina https://arxiv.org/list/cs.RO/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).