Metraipolis › archive › dc_9bb7ab3d4659

Finger-to-Ear ECG: Systematic Evaluation of an Earbud-Based Cardiac Monitoring Approach — arXiv:2609.24530

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.24530
License (as archived)
CC0-1.0
Archived
2026-10-09T07:03:59.895Z
SHA-256 of the archived text
367f17be4034b888ffb01b416c281eb65d4445818a0486e765e50480f70c41a2
Stable URL of this page
https://metraipolis.com/documento/dc_9bb7ab3d4659

How to cite

Finger-to-Ear ECG: Systematic Evaluation of an Earbud-Based Cardiac Monitoring Approach — arXiv:2609.24530 — arXiv (en), https://arxiv.org/abs/2609.24530 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_9bb7ab3d4659 (Metraipolis archive dc_9bb7ab3d4659, sha256 367f17be4034b888ffb01b416c281eb65d4445818a0486e765e50480f70c41a2)
BibTeX
@misc{dc9bb7ab3d4659,
  title = {Finger-to-Ear ECG: Systematic Evaluation of an Earbud-Based Cardiac Monitoring Approach — arXiv:2609.24530},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.24530},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_9bb7ab3d4659; sha256 367f17be4034b888ffb01b416c281eb65d4445818a0486e765e50480f70c41a2},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.24530. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Ear-ECG enables unobtrusive cardiac monitoring, but existing approaches often struggle with low signal amplitudes and limited morphology preservation. We evaluate a finger-to-ear ECG paradigm that combines an in-ear electrode with a rear housing finger-contact electrode in a speaker-equipped earbud. A study with 30 participants investigated four finger-to-ear electrode geometries against chest-reference ECG and additionally assessed robustness under music playback, talking, and walking disturbances. Left-finger configurations achieved R peak detection F1-scores >99% with high agreement of key ECG morphology features. In contrast, right finger configurations as well as walking led to severe signal degradation. The results reveal a trade-off: while cross-body setups provided the highest signal fidelity, users preferred same-side contacts for comfort reasons. This establishes finger-to-ear ECG as a robust, morphology-aware paradigm for opportunistic sensing in earables.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-22 in cs.HC).
Categorie arXiv: Human-Computer Interaction (cs.HC).
Pagina del lavoro: https://arxiv.org/abs/2609.24530 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-09T06:56:29.240Z dalla pagina https://arxiv.org/catchup/cs.HC/2026-09-22?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).