Metraipolis › archive › dc_9b985f818aae

Radiomics--Foundation Fusion for Interpretable RCC Classification: Internal Benchmarking and Exploratory External Transfer — arXiv:2609.26578

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.26578
License (as archived)
CC0-1.0
Archived
2026-10-08T16:39:45.074Z
SHA-256 of the archived text
c752cc9b19b368792bc7b1dd7a50f4ec0c66c3e18226c04a2997cd40edd67ec3
Stable URL of this page
https://metraipolis.com/documento/dc_9b985f818aae

How to cite

Radiomics--Foundation Fusion for Interpretable RCC Classification: Internal Benchmarking and Exploratory External Transfer — arXiv:2609.26578 — arXiv (en), https://arxiv.org/abs/2609.26578 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_9b985f818aae (Metraipolis archive dc_9b985f818aae, sha256 c752cc9b19b368792bc7b1dd7a50f4ec0c66c3e18226c04a2997cd40edd67ec3)
BibTeX
@misc{dc9b985f818aae,
  title = {Radiomics--Foundation Fusion for Interpretable RCC Classification: Internal Benchmarking and Exploratory External Transfer — arXiv:2609.26578},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.26578},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_9b985f818aae; sha256 c752cc9b19b368792bc7b1dd7a50f4ec0c66c3e18226c04a2997cd40edd67ec3},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.26578. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Accurate preoperative subtype classification of renal cell carcinoma (RCC) from contrast-enhanced CT remains clinically challenging because clear cell RCC (ccRCC) and non-clear cell RCC often show overlapping imaging appearances. This study evaluates whether foundation representations reduce reliance on handcrafted radiomics, or whether radiomics remains complementary for interpretable tumour characterisation. We compared radiomics, conventional CNN features, MedicalNet-pretrained features, MedVAE representations, and fusion variants for binary ccRCC classification on KiTS23, reporting area under the receiver operating characteristic curve (AUC) with bootstrap confidence intervals and average precision (AP) as a complementary class-imbalance-sensitive metric. We further assessed branch-removal ablation, TCGA/AIMI external transfer, and interpretability using radiomics permutation importance and gate-level analysis. Internally, 3D MedVAE gated fusion achieved the best performance, with an AUC of 82.7% and AP of 92.2%. On the external TCGA cohort, the same model achieved an AUC of 79.5% and AP of 98.9%, although specificity remains uncertain because only two external non-ccRCC cases were available. Gate analysis showed a radiomics-dominant fusion regime, suggesting that foundation representations acted as case-dependent refinement signals rather than replacements for structured tumour descriptors. These findings support radiomics as a complementary and clinically interpretable component of CT-based RCC characterisation in the foundation-model era.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-23 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2609.26578 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-08T15:56:18.212Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-23?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).