Metraipolis › archive › dc_9a866dc288c2
A sensor-driven physics-informed neural network for real-time occupant-centric space heating control — arXiv:2611.01723
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.01723
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-03T18:37:01.803Z
- SHA-256 of the archived text
912350f6a1b8f5d90b6650698051784bf2fd3c764a034ec906979714c65c5987- Stable URL of this page
https://metraipolis.com/documento/dc_9a866dc288c2
How to cite
A sensor-driven physics-informed neural network for real-time occupant-centric space heating control — arXiv:2611.01723 — arXiv (en), https://arxiv.org/abs/2611.01723 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_9a866dc288c2 (Metraipolis archive dc_9a866dc288c2, sha256 912350f6a1b8f5d90b6650698051784bf2fd3c764a034ec906979714c65c5987)
BibTeX
@misc{dc9a866dc288c2,
title = {A sensor-driven physics-informed neural network for real-time occupant-centric space heating control — arXiv:2611.01723},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.01723},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_9a866dc288c2; sha256 912350f6a1b8f5d90b6650698051784bf2fd3c764a034ec906979714c65c5987},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.01723. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Conventional space heating systems typically rely on single or sparse fixed-point temperature measurements, overlooking non-uniform indoor temperature distributions, transient thermal dynamics, and occupant-specific comfort requirements. This study explores an occupant-centric control strategy that aims to maintain the desired temperature around the occupant location. Spatially and temporally varying temperature fields, together with occupant mobility, make real-time local temperature estimation challenging. To address this challenge, we propose a control-oriented Physics-Informed Neural Network (PINN) model for indoor temperature-field prediction. Conventional PINNs rely on explicit time inputs and assume consistent temporal patterns across samples, which limits adaptability under variable initial conditions and heating sequences. The proposed model infers temporal dynamics implicitly from spatial coordinates and limited sensor measurements, improving robustness to changes in initial conditions and external disturbances. The method was validated across nine horizontal sensing planes in three controlled room-scale configurations. Against a validated COMSOL Multiphysics simulation, the PINN predicted the evaluated temperature fields with a maximum relative error below 1.85% across validation cases. These predictions supported an occupant-centric space heating control scheme. Compared with COMSOL-based offline control, the PINN-based system achieved an average prediction error of around 0.67%, and its rapid inference supports real-time occupant-centric control implementation. This work represents a move away from reliance on fixed-point temperature measurements in space heating control to an occupant-centric control strategy informed by real-time environmental feedback. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.LG, nuovi lavori del giorno). Categorie arXiv: Machine Learning (cs.LG) ; Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2611.01723 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-03T18:12:54.519Z dalla pagina https://arxiv.org/list/cs.LG/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).