Metraipolis › archive › dc_9a831fc3a018
Informed Sinogram Interpolation for Sparse View Reconstruction — arXiv:2609.18415
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.18415
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-15T18:31:01.614Z
- SHA-256 of the archived text
76b69cf7ebe05ee81c1ed48a7f03bd286be4ea5f0e415ebd7a9551d151e95fca- Stable URL of this page
https://metraipolis.com/documento/dc_9a831fc3a018
How to cite
Informed Sinogram Interpolation for Sparse View Reconstruction — arXiv:2609.18415 — arXiv (en), https://arxiv.org/abs/2609.18415 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_9a831fc3a018 (Metraipolis archive dc_9a831fc3a018, sha256 76b69cf7ebe05ee81c1ed48a7f03bd286be4ea5f0e415ebd7a9551d151e95fca)
BibTeX
@misc{dc9a831fc3a018,
title = {Informed Sinogram Interpolation for Sparse View Reconstruction — arXiv:2609.18415},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.18415},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_9a831fc3a018; sha256 76b69cf7ebe05ee81c1ed48a7f03bd286be4ea5f0e415ebd7a9551d151e95fca},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.18415. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Computed tomography (CT) has been widely used in medical examinations and non-destructive testing. Micro-CT (microfocus X-ray CT system) is an advanced version that can observe the internal structures of small objects. However, secondary radiation can prevent micro-CT from imaging the full structure of the object. Given the same amount of secondary scans as primary scans, simple subtraction solves the problem at the price of doubled acquisition time. To reduce the acquisition time, one aims to limit the secondary scans to as few imaging angles as possible and interpolate to recover the missing data. Different interpolation methods have been explored for limited-angle tomography, such as polynomial or spline interpolation, compressive sensing, deep learning, etc. In contrast to many of these scenarios, the secondary imaging setup considered in this paper often exhibits simple sinusoidal structures that are not exploited directly by any of the aforementioned approaches. This paper aims to fill this gap with a continuous mathematical model describing the secondary sinogram only with information from the projection space. Building on this model, we propose an interpolation method that effectively interpolates secondary scans from limited observations. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-17 in eess.IV). Categorie arXiv: Image and Video Processing (eess.IV). Pagina del lavoro: https://arxiv.org/abs/2609.18415 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-15T18:00:31.618Z dalla pagina https://arxiv.org/catchup/eess.IV/2026-09-17?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).