Metraipolis › archive › dc_9a27e889e33e
Magnonic cavity-enhanced quantum magnetometry with nitrogen-vacancy centre ensembles — arXiv:2610.11350
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.11350
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-09T06:39:24.940Z
- SHA-256 of the archived text
1d1fe7ecf800c6cda8c8f751dde4d585f4fa1229a8e67c801d60a48136bb192f- Stable URL of this page
https://metraipolis.com/documento/dc_9a27e889e33e
How to cite
Magnonic cavity-enhanced quantum magnetometry with nitrogen-vacancy centre ensembles — arXiv:2610.11350 — arXiv (en), https://arxiv.org/abs/2610.11350 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_9a27e889e33e (Metraipolis archive dc_9a27e889e33e, sha256 1d1fe7ecf800c6cda8c8f751dde4d585f4fa1229a8e67c801d60a48136bb192f)
BibTeX
@misc{dc9a27e889e33e,
title = {Magnonic cavity-enhanced quantum magnetometry with nitrogen-vacancy centre ensembles — arXiv:2610.11350},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.11350},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_9a27e889e33e; sha256 1d1fe7ecf800c6cda8c8f751dde4d585f4fa1229a8e67c801d60a48136bb192f},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.11350. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Nitrogen-vacancy (NV) centre ensembles are leading room-temperature magnetometers, but their sensitivity is usually extracted from a single resonance and relies on external microwave and bias-field hardware. This work proposes a chip-scale NV magnetometer built around a one-dimensional YIG/CoFeB magnonic crystal, in which a single structural defect forms a passive magnonic cavity and integrated permanent magnets supply the bias field. Micromagnetic simulations show a defect-localised spin-wave mode at 2.910 GHz inside the 2.5-3.0 GHz magnonic band gap, 40 MHz from the NV zero-field splitting, with a band structure that matches an independent plane-wave calculation. A Tavis-Cummings/Lindblad model in which the microwave reaches the NV ensemble through this mode predicts a hyperfine-resolved optically detected magnetic resonance spectrum that is strong only within the mode linewidth, and a dispersive homodyne response with one steep edge per $^{14}$N hyperfine line. The master-equation solutions agree with the closed-form homodyne steady state ($R^2 > 0.9999$) and with an approximate analytic ODMR theory (peak positions within 0.012 MHz). For a critically coupled readout with room-temperature electronics, combining the three edges gives a projected sensitivity of 93 pT/$\sqrt{\rm Hz}$, a $\sqrt{3}$-fold gain over the best single edge. Mapping the sensitivity against the NV-magnon coupling reveals an optimum near $g_{\rm ens}/2\pi \approx 0.2$-$0.4$ MHz, where it reaches 72 pT/$\sqrt{\rm Hz}$ for a 0.64 MHz spin linewidth and 19 pT/$\sqrt{\rm Hz}$ for 0.17 MHz, with thermal limits of 6.6 and 1.7 pT/$\sqrt{\rm Hz}$. The antenna-mode coupling, the NV-magnon coupling and the spin linewidth are therefore the main design levers.
Tema degli esploratori: fisica e astronomia (elenco arXiv quant-ph, nuovi lavori del giorno).
Categorie arXiv: Mesoscale and Nanoscale Physics (cond-mat.mes-hall) ; Quantum Physics (quant-ph).
Pagina del lavoro: https://arxiv.org/abs/2610.11350 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-09T05:58:47.110Z dalla pagina https://arxiv.org/list/quant-ph/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).