Metraipolis › archive › dc_9a235b47ab91
SCoPE-Reg: Efficient Rigid Ultrasound Slice-to-Volume Registration via State-Space Correlation and Closed-Form Pose Estimation — arXiv:2608.28715
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.28715
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T09:59:56.030Z
- SHA-256 of the archived text
cb452e7d2782659b336920ef66cd8aceff2e7c4b3da5eeb6802142a3e4a1b9cf- Stable URL of this page
https://metraipolis.com/documento/dc_9a235b47ab91
How to cite
SCoPE-Reg: Efficient Rigid Ultrasound Slice-to-Volume Registration via State-Space Correlation and Closed-Form Pose Estimation — arXiv:2608.28715 — arXiv (en), https://arxiv.org/abs/2608.28715 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_9a235b47ab91 (Metraipolis archive dc_9a235b47ab91, sha256 cb452e7d2782659b336920ef66cd8aceff2e7c4b3da5eeb6802142a3e4a1b9cf)
BibTeX
@misc{dc9a235b47ab91,
title = {SCoPE-Reg: Efficient Rigid Ultrasound Slice-to-Volume Registration via State-Space Correlation and Closed-Form Pose Estimation — arXiv:2608.28715},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.28715},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_9a235b47ab91; sha256 cb452e7d2782659b336920ef66cd8aceff2e7c4b3da5eeb6802142a3e4a1b9cf},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.28715. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Ultrasound-guided interventions can require localization of an untracked 2D frame within a 3D anatomical reference. Rigid slice-to-volume registration (SVR) estimates this six-degree-of-freedom pose but remains challenging because of limited anatomical context, acoustic artifacts, and view-dependent appearance. Existing methods often use dense cross-attention, whose cost scales with the product of slice and volume token counts, or direct pose regression without explicit correspondence constraints. We introduce SCoPE-Reg, combining state-space slice--volume interaction, dense 3D coordinate prediction, and parameter-free weighted Kabsch estimation. On SVR tasks from CAMUS and $\mu$-RegPro, SCoPE-Reg yields mean target registration errors of $0.73$ mm and $2.27$ mm against $1.24$ mm and $2.63$ mm for the state of the art (SOTA), reduces peak error on CAMUS by 56% below SOTA ($12.5\!\to\!5.5$ mm), and registers $100\%$ and $80\%$ of frames within $3$ mm. On CAMUS at $128^2$ it retains the lowest error at increasing pose-perturbation magnitude. It holds $6.49$ M parameters independent of resolution, sustaining $51$ FPS at $512^2$. SCoPE-Reg establishes a SOTA in rigid ultrasound SVR: by coupling correspondence-based accuracy with bounded worst-case error and resolution-independent cost, it becomes viable at native acquisition resolution during intervention, where prior methods trade accuracy, reliability, or frame rate against one another. Supplementary code provided and will be open-sourced upon acceptance. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-01 in cs.CV). Categorie arXiv: Image and Video Processing (eess.IV) ; Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2608.28715 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-17T09:28:48.245Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).