Metraipolis › archive › dc_99594ea30238

Measurement-Error-Aware Causal Distributed-Lag Quantile Modeling of Indoor Air Pollution and Short-Term Lung-Function Deterioration — arXiv:2609.31646

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.31646
License (as archived)
CC0-1.0
Archived
2026-10-07T20:59:12.395Z
SHA-256 of the archived text
57b917694299f453d2184a6cf1f6375b66d6fb8c40302b4c85ab282a422c3eee
Stable URL of this page
https://metraipolis.com/documento/dc_99594ea30238

How to cite

Measurement-Error-Aware Causal Distributed-Lag Quantile Modeling of Indoor Air Pollution and Short-Term Lung-Function Deterioration — arXiv:2609.31646 — arXiv (en), https://arxiv.org/abs/2609.31646 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_99594ea30238 (Metraipolis archive dc_99594ea30238, sha256 57b917694299f453d2184a6cf1f6375b66d6fb8c40302b4c85ab282a422c3eee)
BibTeX
@misc{dc99594ea30238,
  title = {Measurement-Error-Aware Causal Distributed-Lag Quantile Modeling of Indoor Air Pollution and Short-Term Lung-Function Deterioration — arXiv:2609.31646},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.31646},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_99594ea30238; sha256 57b917694299f453d2184a6cf1f6375b66d6fb8c40302b4c85ab282a422c3eee},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.31646. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Low-cost indoor air-quality sensors could support personalized asthma prevention, but their nonlinear measurement error, delayed exposure effects, time-varying confounding, and heterogeneous lower-tail responses limit risk estimation. We present CAUSALQUANT-ASTHMA, a measurement-error-aware causal quantile distributed-lag framework for short-horizon peak expiratory flow analysis. Sparse reference measurements train a nonlinear calibration model; stabilized sequential generalized-propensity weights address measured exposure assignment; and a susceptibility-modulated, smooth, noncrossing quantile model estimates lag-specific and sustained-exposure contrasts. Because no authorized cohort simultaneously provided dense indoor sensing, reference co-location, and outcome-compatible longitudinal data, evaluation used five semi-synthetic panels with known counterfactual truth, 150 patients and 12,600 patient-days per realization. Across eight methods, CAUSALQUANT achieved a dose-response integrated absolute error of 0.304 plus or minus 0.094, improving 24.2 percent over the strongest measurement-error and propensity-weighted baseline. It also obtained the lowest overall pinball loss, 1.065, while maintaining zero quantile crossings and 78.1 percent coverage for the nominal 80 percent interval. Sensor calibration reduced held-out exposure RMSE by 33.7 percent. Stress tests quantified degradation under sensor noise, missing personal measurements, and hidden confounding. These findings establish methodological feasibility and reproducibility, not clinical effectiveness; prospective, governance-approved external validation is required before patient-level interpretation or deployment.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-29 in cs.AI).
Categorie arXiv: Applications (stat.AP) ; Artificial Intelligence (cs.AI); Computers and Society (cs.CY); Machine Learning (cs.LG).
Pagina del lavoro: https://arxiv.org/abs/2609.31646 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T20:29:01.978Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).