Metraipolis › archive › dc_994103c75022

Nonlinear Fault Tolerant Control of Wind Turbine Pitch Systems: A Comparative Study — arXiv:2611.09674

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.09674
License (as archived)
CC0-1.0
Archived
2026-11-09T23:03:35.917Z
SHA-256 of the archived text
4904d4fefba0343f3a15da4ec2c841de109cd09ea58d1f1d33f175f0837e53ee
Stable URL of this page
https://metraipolis.com/documento/dc_994103c75022

How to cite

Nonlinear Fault Tolerant Control of Wind Turbine Pitch Systems: A Comparative Study — arXiv:2611.09674 — arXiv (en), https://arxiv.org/abs/2611.09674 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_994103c75022 (Metraipolis archive dc_994103c75022, sha256 4904d4fefba0343f3a15da4ec2c841de109cd09ea58d1f1d33f175f0837e53ee)
BibTeX
@misc{dc994103c75022,
  title = {Nonlinear Fault Tolerant Control of Wind Turbine Pitch Systems: A Comparative Study — arXiv:2611.09674},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.09674},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_994103c75022; sha256 4904d4fefba0343f3a15da4ec2c841de109cd09ea58d1f1d33f175f0837e53ee},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.09674. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Electro-hydraulic pitch systems account for about one fifth of wind-turbine failures, motivating the development of resilient control strategies for fault mitigation. The study considers a large set of robust nonlinear control designs of different feedback principles and architectures, and assesses their fault-tolerant capabilities in comparison to each other and against the industrial standard, i.e. the Proportional-Integral (PI) controller. The implementation and tuning of each scheme is based on a high-fidelity simulator to ensure nominal performance, whereas each controller is deployed unchanged on an experimental apparatus that includes a full-scale electro-hydraulic pitch system. The comparative evaluation of the considered fault-tolerant solutions is carried out through several tests that cover nominal operation and twenty-five representative fault scenarios, including sensor, process, and actuator faults. The analysis highlights the trade-off between performance preservation under faults and increased actuator chattering. The experimental results show that introducing a dynamic input-reconstruction module into the design of the nonlinear controllers significantly reduces actuator chatter without compromising their fault-tolerant properties.

Tema degli esploratori: calcolo e infrastrutture (elenco arXiv eess.SY, nuovi lavori del giorno).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2611.09674 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-09T22:58:52.106Z dalla pagina https://arxiv.org/list/eess.SY/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).