Metraipolis › archive › dc_98d467ce0224

Characterization of the indoor near-field and far-field aerosol transmission in a model commercial office building — Europe PMC PPR:PPR290380

Source
Europe PMC
Original
https://europepmc.org/article/PPR/PPR290380
DOI
10.1101/2021.02.25.21252239
License (as archived)
CC0-1.0
Archived
2026-11-05T19:09:11.598Z
SHA-256 of the archived text
2e5835d7220f5df27b00eb1b96160371774223116e27a57641ae31aa313a4467
Stable URL of this page
https://metraipolis.com/documento/dc_98d467ce0224

How to cite

Characterization of the indoor near-field and far-field aerosol transmission in a model commercial office building — Europe PMC PPR:PPR290380 — Europe PMC, https://europepmc.org/article/PPR/PPR290380 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_98d467ce0224 (Metraipolis archive dc_98d467ce0224, sha256 2e5835d7220f5df27b00eb1b96160371774223116e27a57641ae31aa313a4467)
BibTeX
@misc{dc98d467ce0224,
  title = {Characterization of the indoor near-field and far-field aerosol transmission in a model commercial office building — Europe PMC PPR:PPR290380},
  howpublished = {Europe PMC},
  url = {https://europepmc.org/article/PPR/PPR290380},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_98d467ce0224; sha256 2e5835d7220f5df27b00eb1b96160371774223116e27a57641ae31aa313a4467},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC, https://europepmc.org/article/PPR/PPR290380. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

To simulate the exposure potential of infectious aerosol such as SARS-CoV-2 in an office building setting, experimental studies for airborne particle transmission have been conducted in a model commercial office building at the Oak Ridge National Laboratory. The synthetic test aerosol particles had diameters similar to that of viral particles, in the nanometer size range of genetic fragments. Thus, the test aerosol provided a realistic representation of SARS-CoV-2 viral particle transmission. The study results, which are still being analyzed carefully at the present, suggest that in a door-closed single room setting, the heating, ventilating, and air-conditioning (HVAC) system can facilitate aerosol transmission, and 10 measuring points in a single room report the normalized concentration ranged from 0.45 – 0.66. Additionally, at a measuring point 6 feet away from the source, the aerosol concentration can reach a plateau normalized concentration of about 0.6 within 30 minutes. When interior doors were closed, aerosol particle transmission into adjacent rooms occurred through the building HVAC system, at a lower rate compared to the open-door scenario. If the interior doors were open, however, then the transmission into adjacent rooms depends on building indoor air movement and distance from the source. The building HVAC system provided an approximately less than 10% aerosol transmission rate, while transmission through a door opening can add up to 40% of transmission into adjacent rooms from the source location. Footnote: This manuscript has been authored by UT-Battelle, LLC, under contract DE-AC05-00OR22725 with the US Department of Energy (DOE). The US government retains and the publisher, by accepting the article for publication, acknowledges that the US government retains a nonexclusive, paid-up, irrevocable, worldwide license to publish or reproduce the published form of this manuscript, or allow others to do so, for US government purposes. DOE will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan ( http://energy.gov/downloads/doe-public-access-plan ).

Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera).
Pubblicazione: medRxiv, 2021 (prima pubblicazione 2021-03-01).
Identificativi: DOI 10.1101/2021.02.25.21252239.
Pagina: https://europepmc.org/article/PPR/PPR290380 — https://doi.org/10.1101/2021.02.25.21252239. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0.
Letto il 2026-11-05T19:03:16.978Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.