Automated Perceptually-Motivated Assessment of Photographic Consistency in Paired Clinical Photographs: Pipeline Development and Internal Evaluation — arXiv:2609.15144
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.15144
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T01:53:22.660Z
- SHA-256 of the archived text
2dbb91388568852d17aaf8e7007a9e932b45075784fafd04be6e350f690995f1- Stable URL of this page
https://metraipolis.com/documento/dc_986e4cbea5ea
How to cite
Automated Perceptually-Motivated Assessment of Photographic Consistency in Paired Clinical Photographs: Pipeline Development and Internal Evaluation — arXiv:2609.15144 — arXiv (en), https://arxiv.org/abs/2609.15144 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_986e4cbea5ea (Metraipolis archive dc_986e4cbea5ea, sha256 2dbb91388568852d17aaf8e7007a9e932b45075784fafd04be6e350f690995f1)
BibTeX
@misc{dc986e4cbea5ea,
title = {Automated Perceptually-Motivated Assessment of Photographic Consistency in Paired Clinical Photographs: Pipeline Development and Internal Evaluation — arXiv:2609.15144},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.15144},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_986e4cbea5ea; sha256 2dbb91388568852d17aaf8e7007a9e932b45075784fafd04be6e350f690995f1},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.15144. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Purpose: Paired pre- and post-operative photographs are the standard unit of evidence for plastic surgical outcomes, yet no objective metric verifies whether two images of the same patient were captured under conditions consistent for comparison. Approach: We developed a perceptually motivated pipeline that analyzes pre/post pairs across thirteen calibrated sub-metrics, partitioned by unsupervised correlation-structure analysis into five data-driven clusters (photometric, texture / sharpness, pose, illumination direction, and pitch), averaged within each cluster and combined across clusters by a weighted sum into a single consistency score. Each sub-metric is calibrated so that its median difference across published within-patient pairs scores 0.5, which is a reference point and carries no pass/fail meaning. The pipeline was calibrated on 134 matched within-patient published pre/post pairs and evaluated against identical-image pairs, synthetic-perturbation pairs, and 134 mismatched cross-publication pairs. Results: The master consistency score S separated matched from mismatched pairs (sensitivity index d' = 2.15, 95% confidence interval (CI) [1.83, 2.55]; area under the receiver operating characteristic curve AUC = 0.928, 95% CI [0.896, 0.959]), closely matching Gaussian-equal-variance predictions. The three head-pose angles did not fall in one cluster: yaw and roll grouped together while pitch separated. Identical pairs scored at ceiling (S = 0.99) and the master score fell monotonically with perturbation magnitude on all five perturbation axes. Conclusions: The score quantifies photographic comparability, not aesthetic or surgical quality, and provides a freely available web tool for auditing the photographic comparability of pre/post pairs, pending validation against expert judgment. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-15 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.15144 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T01:25:23.640Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-15?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).