Metraipolis › archive › dc_97adf5a34664

Detection of Synchronized AI Data Center Load Episodes Using SCADA Telemetry — arXiv:2609.18997

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.18997
License (as archived)
CC0-1.0
Archived
2026-10-15T18:22:41.715Z
SHA-256 of the archived text
3c6058f3052ed1e9b3c81c227c484792a9027c140fcad56d7c4bbdccbc1e249a
Stable URL of this page
https://metraipolis.com/documento/dc_97adf5a34664

How to cite

Detection of Synchronized AI Data Center Load Episodes Using SCADA Telemetry — arXiv:2609.18997 — arXiv (en), https://arxiv.org/abs/2609.18997 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_97adf5a34664 (Metraipolis archive dc_97adf5a34664, sha256 3c6058f3052ed1e9b3c81c227c484792a9027c140fcad56d7c4bbdccbc1e249a)
BibTeX
@misc{dc97adf5a34664,
  title = {Detection of Synchronized AI Data Center Load Episodes Using SCADA Telemetry — arXiv:2609.18997},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.18997},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_97adf5a34664; sha256 3c6058f3052ed1e9b3c81c227c484792a9027c140fcad56d7c4bbdccbc1e249a},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.18997. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

AI data centers running distributed training workloads impose episodic, spatially correlated active-power disturbances on the transmission grid. These synchronized episodes increase cross-substation load correlation and limit the diversification benefit that reserve margin planning assumes. Conventional energy management systems evaluate each substation independently and do not extract the cross-substation statistical structure that defines a synchronized episode. This paper develops a detection method that identifies synchronized AI data-center load episodes from standard active-power telemetry without new instrumentation, trained classifiers, or labeled data. The method computes a Synchronization Index, the dominant eigenvalue fraction of a sliding sample covariance matrix across substations. A cumulative-sum (CUSUM) sequential test converts the index into a delay-bounded episode alarm. The same eigen decomposition yields, at no additional cost, a dominant eigenvector that attributes a detected episode to the substations that drive it. Tests on a real-time digital simulator (RTDS) model of the IEEE 39-bus system with three AI data-center buses show that the method separates episode and normal windows with a wide margin over chance and attributes episode participation at substation granularity.

Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-17 in eess.SY).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2609.18997 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-15T17:54:20.035Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-09-17?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).