Metraipolis › archive › dc_971fa8359c22
Portable Vector NV-Diamond Magnetometer for Shot-Noise-Limited, Drift-Free Operation in Unshielded Environments — arXiv:2609.16901
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.16901
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-15T22:05:59.265Z
- SHA-256 of the archived text
175787626848965db7599e1086e698d90ef40308a7ab1a7859bcb745ae920856- Stable URL of this page
https://metraipolis.com/documento/dc_971fa8359c22
How to cite
Portable Vector NV-Diamond Magnetometer for Shot-Noise-Limited, Drift-Free Operation in Unshielded Environments — arXiv:2609.16901 — arXiv (en), https://arxiv.org/abs/2609.16901 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_971fa8359c22 (Metraipolis archive dc_971fa8359c22, sha256 175787626848965db7599e1086e698d90ef40308a7ab1a7859bcb745ae920856)
BibTeX
@misc{dc971fa8359c22,
title = {Portable Vector NV-Diamond Magnetometer for Shot-Noise-Limited, Drift-Free Operation in Unshielded Environments — arXiv:2609.16901},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.16901},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_971fa8359c22; sha256 175787626848965db7599e1086e698d90ef40308a7ab1a7859bcb745ae920856},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.16901. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Ensemble nitrogen-vacancy (NV) diamond magnetometers combine high sensitivity with vector-field reconstruction, but practical deployment is limited by errors arising from high-frequency laser noise during short-duration operations and slow-varying gain fluctuations and offset drift during long-term operation. Here, we present an integrated digital architecture for achieving NV magnetometry stability across distinct timescales. A dynamic differential readout continuously balances fluorescence and reference channels to suppress correlated laser noise. Second-derivative Lorentzian lineshape tracking enables in-situ correction of slope variations arising from slow changes in gain and optical excitation. We further identify temperature-induced bias-magnet fluctuations as a dominant source of long-term drift and introduce a magnetic eigenvector transformation that uses the intrinsic response of NV resonances to eliminate these variations. We show, under unshielded ambient conditions, that this architecture achieves an off-resonance noise factor of 1.0 $\pm$ 0.1, matching the fundamental limit with ten-fold suppression of long-term drift, enabling stable, field-ready quantum magnetometry. Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-09-16 in quant-ph). Categorie arXiv: Quantum Physics (quant-ph) ; Applied Physics (physics.app-ph). Pagina del lavoro: https://arxiv.org/abs/2609.16901 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-15T21:52:12.814Z dalla pagina https://arxiv.org/catchup/quant-ph/2026-09-16?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).