Metraipolis › archive › dc_94b3b4cc2af9
Clinical Knowledge Graphs for Chest X-Ray Device Reasoning — arXiv:2609.29536
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.29536
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T04:26:13.136Z
- SHA-256 of the archived text
2fbe54044be60a0f31c5388ca862ee83d5637164621a14aefc00645c20f63351- Stable URL of this page
https://metraipolis.com/documento/dc_94b3b4cc2af9
How to cite
Clinical Knowledge Graphs for Chest X-Ray Device Reasoning — arXiv:2609.29536 — arXiv (en), https://arxiv.org/abs/2609.29536 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_94b3b4cc2af9 (Metraipolis archive dc_94b3b4cc2af9, sha256 2fbe54044be60a0f31c5388ca862ee83d5637164621a14aefc00645c20f63351)
BibTeX
@misc{dc94b3b4cc2af9,
title = {Clinical Knowledge Graphs for Chest X-Ray Device Reasoning — arXiv:2609.29536},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.29536},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_94b3b4cc2af9; sha256 2fbe54044be60a0f31c5388ca862ee83d5637164621a14aefc00645c20f63351},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.29536. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Chest radiographs are routinely used to verify the position of catheters, tubes, and other support devices. Existing image models often return labels or segmentations, while report-processing systems structure text without access to image geometry. We present an uncertainty-aware clinical knowledge graph that represents device instances, tip estimates, placement assessments, provenance, report events, and temporal links as separate but connected evidence. We evaluate the implemented visual graph layer using saved predictions from the complete RANZCR CLiP test archive, comprising 30,083 studies from 3,255 patients across five non-overlapping outer folds. The graph builder materializes 914,632 B7 evidence nodes and 884,549 typed relationships. All 118,647 B7 predicted-device nodes retain tip covariance, placement probabilities, fragment provenance, and fragment counts, whereas the direct B2 baseline retains none of these fields. We further define typed data contracts, uncertainty representations, abstention rules, report-image grounding, and longitudinal query mechanisms for extending the graph to report-bearing cohorts. The reported graph-materialization analysis is post-hoc descriptive and does not establish report grounding, longitudinal performance, or clinical utility. It demonstrates a reproducible foundation for evidence-preserving AI reasoning over chest X-ray device assessments. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-25 in cs.AI). Categorie arXiv: Artificial Intelligence (cs.AI) ; Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.29536 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-08T03:50:57.786Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-25?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).