Metraipolis › archive › dc_9436eda19a8d

Energy-flux noise induced by imperfections of the Gaussian beam in the Li-Baker HFGW detector — arXiv:2610.39248

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.39248
License (as archived)
CC0-1.0
Archived
2026-11-01T02:55:17.664Z
SHA-256 of the archived text
3db05b668c793daa7aad1051b565a278aa0fc96e29adea7cb603f4f0f2bce9e7
Stable URL of this page
https://metraipolis.com/documento/dc_9436eda19a8d

How to cite

Energy-flux noise induced by imperfections of the Gaussian beam in the Li-Baker HFGW detector — arXiv:2610.39248 — arXiv (en), https://arxiv.org/abs/2610.39248 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_9436eda19a8d (Metraipolis archive dc_9436eda19a8d, sha256 3db05b668c793daa7aad1051b565a278aa0fc96e29adea7cb603f4f0f2bce9e7)
BibTeX
@misc{dc9436eda19a8d,
  title = {Energy-flux noise induced by imperfections of the Gaussian beam in the Li-Baker HFGW detector — arXiv:2610.39248},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.39248},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_9436eda19a8d; sha256 3db05b668c793daa7aad1051b565a278aa0fc96e29adea7cb603f4f0f2bce9e7},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.39248. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

This paper investigates the energy-flux noise induced by imperfections of the Gaussian beam (GB) in the Li-Baker high-frequency gravitational wave (HFGW) detector. Modeling these imperfections with higher-order Laguerre-Gaussian (LG) beams, we analytically derive the resulting noise-to-signal ratio for both co- and cross-polarized $\mathrm{LG}_{nl}$ modes. It is found that higher-order co-polarized LG beams generate no tangential energy-flux noise at the optimal detection plane ($\phi=\pi/2$ or $3\pi/2$), whereas higher-order cross-polarized LG beams introduce non-negligible noise. Specifically, for an individual higher-order cross-polarized $\mathrm{LG}_{nl}$ mode under our representative parameters, maintaining the noise-to-signal ratio below unity typically requires the power fraction to satisfy $\sigma_{nl}<10^{-46}$, with the $\mathrm{LG}_{01}$ mode imposing the most stringent constraint of $\sigma_{01}<6.0\times10^{-49}$. Monte Carlo simulations suggest that the total power fraction $\sigma_{\mathrm{total}}$ of multiple higher-order cross-polarized $\mathrm{LG}_{nl}$ modes needs to remain below $10^{-49}$. Consequently, we propose employing a polarization filter to retain only the co-polarized component of the GB adopted in the practical experiment, thereby suppressing the noise while preserving signal integrity. These results provide theoretical guidance for noise control in the Li-Baker HFGW detector.

Tema degli esploratori: fisica e astronomia (elenco arXiv astro-ph.IM, nuovi lavori del giorno).
Categorie arXiv: General Relativity and Quantum Cosmology (gr-qc) ; Instrumentation and Methods for Astrophysics (astro-ph.IM).
Pagina del lavoro: https://arxiv.org/abs/2610.39248 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-01T02:22:13.275Z dalla pagina https://arxiv.org/list/astro-ph.IM/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).