Metraipolis › archive › dc_94070a22aa50
Towards High-Throughput Visible Photonic Lanterns for the EMARCOT Project — arXiv:2609.10900
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.10900
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T07:00:41.150Z
- SHA-256 of the archived text
3bd5daabafeeb61870e82f4a14bf70534119732077717cb5ba73d479c39eb540- Stable URL of this page
https://metraipolis.com/documento/dc_94070a22aa50
How to cite
Towards High-Throughput Visible Photonic Lanterns for the EMARCOT Project — arXiv:2609.10900 — arXiv (en), https://arxiv.org/abs/2609.10900 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_94070a22aa50 (Metraipolis archive dc_94070a22aa50, sha256 3bd5daabafeeb61870e82f4a14bf70534119732077717cb5ba73d479c39eb540)
BibTeX
@misc{dc94070a22aa50,
title = {Towards High-Throughput Visible Photonic Lanterns for the EMARCOT Project — arXiv:2609.10900},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.10900},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_94070a22aa50; sha256 3bd5daabafeeb61870e82f4a14bf70534119732077717cb5ba73d479c39eb540},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.10900. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Photonic EMARCOT is an innovative project involving Spanish, German and Australian research institutes that aims to integrate multiple Optical Tube Assemblies (OTAs) using photonic lanterns. The "Pathfinder" prototype, featuring seven OTAs with a 1.1-meter effective aperture, will feed a spectrograph at the Calar Alto Observatory, with first light expected in 2026. We report the fabrication and experimental evaluation of a custom 7x1 multi-mode photonic lantern (MMPL) developed for this framework, featuring seven 25 um core multi-mode inputs merging into a single 50 um core multi-mode output optimized for the visible wavelength range (400-700 nm). Optical characterization centered at 600 nm reveals exceptional channel-to-channel uniformity, with statistical variations close to zero across both bare-fiber and connectorized MMPL configurations. However, the total baseline throughput of this initial device was limited to below 4%. From the refractive index studies, this low throughput is attributed to severe refractive index mismatch between the internal fiber cladding geometry and the structural capillary, which suppresses total internal reflection during the tapering transition. This work establishes an important diagnostic baseline that highlights the necessary fabrication tolerances needed to improve future high-throughput manufacturing processes for precision radial-velocity astronomy. Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-09-11 in astro-ph.IM). Categorie arXiv: Instrumentation and Methods for Astrophysics (astro-ph.IM). Pagina del lavoro: https://arxiv.org/abs/2609.10900 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T06:39:55.814Z dalla pagina https://arxiv.org/catchup/astro-ph.IM/2026-09-11?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).