Metraipolis › archive › dc_93f211829a2d

PhySA: Decoupling Aesthetic and Physical Rewards for Humanoid Locomotion — arXiv:2611.07679

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.07679
License (as archived)
CC0-1.0
Archived
2026-11-06T14:54:02.582Z
SHA-256 of the archived text
61db915f1fe43cde03da3926abbf1f3fe84025666b14c2bf95138718ab4b03a4
Stable URL of this page
https://metraipolis.com/documento/dc_93f211829a2d

How to cite

PhySA: Decoupling Aesthetic and Physical Rewards for Humanoid Locomotion — arXiv:2611.07679 — arXiv (en), https://arxiv.org/abs/2611.07679 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_93f211829a2d (Metraipolis archive dc_93f211829a2d, sha256 61db915f1fe43cde03da3926abbf1f3fe84025666b14c2bf95138718ab4b03a4)
BibTeX
@misc{dc93f211829a2d,
  title = {PhySA: Decoupling Aesthetic and Physical Rewards for Humanoid Locomotion — arXiv:2611.07679},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.07679},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_93f211829a2d; sha256 61db915f1fe43cde03da3926abbf1f3fe84025666b14c2bf95138718ab4b03a4},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.07679. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Humanoid locomotion policies trained without an explicit smoothness objective tend to produce jerky, high-energy gaits that stress actuators. Vision-language models (VLMs) offer an appealing reward source: given a rendered rollout, a VLM returns an aesthetic quality score on [0,10] without task-specific feature engineering. We find, however, that aesthetic preference and physical smoothness point in opposite directions: across four production VLMs, clips with higher joint acceleration receive higher aesthetic scores (mean Pearson r=+0.66). We study PhySA (Physical Smoothness and Aesthetics), which keeps the two on separate, independently removable reward channels: a sparse, asynchronous VLM score and a phase-triggered correction channel that adjusts physical penalty weights from simulator state. Ablations attribute the smoothness gain to the correction channel. On MuJoCo Humanoid-v5 at 2.6M steps, PhySA lowers joint acceleration by 26 to 32% relative to vanilla PPO, Text2Reward, and Eureka (three seeds), at the cost of shorter episodes. In a single extended run it lowers joint acceleration by 59.5% relative to Prompt2Policy, while a three-seed replication shows a smaller, non-significant reduction (7.2%). The gain does not transfer to IsaacLab or the Unitree G1, even after rescaling the smoothness term.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.RO, nuovi lavori del giorno).
Categorie arXiv: Robotics (cs.RO).
Pagina del lavoro: https://arxiv.org/abs/2611.07679 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-06T14:25:57.564Z dalla pagina https://arxiv.org/list/cs.RO/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).