Metraipolis › archive › dc_9389130ac78b

The Effect of Tissue Detection on False Positives of Diffusion-Based Artifact Detection in Histopathology — arXiv:2609.40083

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.40083
License (as archived)
CC0-1.0
Archived
2026-10-07T14:46:53.773Z
SHA-256 of the archived text
bd8bee46f01737af92f970b25bd1a0893d03e6fe6f1c8491dde173dc8ecbdcb7
Stable URL of this page
https://metraipolis.com/documento/dc_9389130ac78b

How to cite

The Effect of Tissue Detection on False Positives of Diffusion-Based Artifact Detection in Histopathology — arXiv:2609.40083 — arXiv (en), https://arxiv.org/abs/2609.40083 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_9389130ac78b (Metraipolis archive dc_9389130ac78b, sha256 bd8bee46f01737af92f970b25bd1a0893d03e6fe6f1c8491dde173dc8ecbdcb7)
BibTeX
@misc{dc9389130ac78b,
  title = {The Effect of Tissue Detection on False Positives of Diffusion-Based Artifact Detection in Histopathology — arXiv:2609.40083},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.40083},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_9389130ac78b; sha256 bd8bee46f01737af92f970b25bd1a0893d03e6fe6f1c8491dde173dc8ecbdcb7},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.40083. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

One-class artifact detectors for whole-slide images learn normal tissue from a clean training pool and flag departures from it. The pool is built by a preprocessing pipeline whose tissue-detection step is usually treated as neutral. We tested whether it is. On 16 annotated slides from The Cancer Genome Atlas, we rebuilt the clean pool of a diffusion-based detector with different tissue detection methods and compared the resulting models in a four-fold cross-validation. Per-slide saturation-Otsu detection excluded normal tissue, chiefly tissue with large clear spaces such as adipose tissue and alveolar parenchyma, and on slides with thick marker ink kept the ink while excluding ordinary tissue. Replacing it with entropy-based detection reduced the false-positive fraction on held-out clean slides from 0.102 to 0.016, in every fold and with a second training seed, without loss of sensitivity; the gain came from the composition of the pool, not its size. Across three tissue detection methods, false positives followed the fraction of such clear-space tissue in the pool, a statistic that needs no labels or training (0.103, 0.016 and 0.009). The effect did not carry over at the same size to a nearest-neighbour detector on foundation-model features. On an external cohort, the curated pool lowered clean-control false positives by about 20%, far less than on the development slides, and the remaining cross-center loss was not explained by stain differences. For one-class quality control, tissue detection decides what the model learns as normal and should be chosen and reported accordingly.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-10-01 in cs.CV).
Categorie arXiv: Image and Video Processing (eess.IV) ; Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2609.40083 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T14:19:00.916Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-10-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).