Capacity Models and Transmission Risk Mitigation: An Engineering Framework to Predict the Effect of Air Disinfection by Germicidal Ultraviolet Radiation — Europe PMC PMID:39359736

Source
Europe PMC (en)
Original
https://europepmc.org/article/MED/39359736
DOI
10.6028/jres.126.057
License (as archived)
CC0-1.0
Archived
2026-11-06T12:38:23.347Z
SHA-256 of the archived text
bf4200eb76564b13aeb0dabd18cfbc26b149158bbdb53a467b8c9fb35aced6a9
Stable URL of this page
https://metraipolis.com/documento/dc_9283ce9dbd91

How to cite

Capacity Models and Transmission Risk Mitigation: An Engineering Framework to Predict the Effect of Air Disinfection by Germicidal Ultraviolet Radiation — Europe PMC PMID:39359736 — Europe PMC (en), https://europepmc.org/article/MED/39359736 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_9283ce9dbd91 (Metraipolis archive dc_9283ce9dbd91, sha256 bf4200eb76564b13aeb0dabd18cfbc26b149158bbdb53a467b8c9fb35aced6a9)
BibTeX
@misc{dc9283ce9dbd91,
  title = {Capacity Models and Transmission Risk Mitigation: An Engineering Framework to Predict the Effect of Air Disinfection by Germicidal Ultraviolet Radiation — Europe PMC PMID:39359736},
  howpublished = {Europe PMC (en)},
  url = {https://europepmc.org/article/MED/39359736},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_9283ce9dbd91; sha256 bf4200eb76564b13aeb0dabd18cfbc26b149158bbdb53a467b8c9fb35aced6a9},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/39359736. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

A first-principles-based model for predicting the effect of germicidal radiation interventions for air disinfection is presented. Calculation of the "capacity" of an intervention expressed in volumetric flow rate allows for a direct comparison against fresh-air dilution ventilation and filtration systems, which are quantified in terms of the clean air provided. A closed-form expression to predict the combined quantitative impact of spatial gradients and mixing currents on the efficiency with which an intervention is applied is introduced. If validated, this would allow for systems to be selected and sized based on simple metrics across a broad range of settings and applications. The expressions developed are compared against available experimental data sets, and future validation efforts are proposed. Additionally, a method to identify an optimal operating capacity for a given setting by comparing costs associated with disease transmission against the cost of capacity is derived using the Wells-Riley equation and presented as an appendix.

Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera).
Pubblicazione: Journal of research of the National Institute of Standards and Technology, 2021 (prima pubblicazione 2021-01-01).
Identificativi: PMID 39359736 · PMCID PMC11418604 · DOI 10.6028/jres.126.057.
Parole chiave degli autori: Efficiency; risk management; Modelling; Air Disinfection; Ultraviolet Germicidal Irradiation; Uvgi; Wells-riley.