Metraipolis › archive › dc_9260d8815ebd
Electromagnetic Micro-Guidewire Control in Large Workspaces — arXiv:2609.16354
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.16354
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-15T22:39:20.710Z
- SHA-256 of the archived text
ef6b1681eeb941d59a2da4bfb246c14420df3708c2951a834849edcd4c65fdde- Stable URL of this page
https://metraipolis.com/documento/dc_9260d8815ebd
How to cite
Electromagnetic Micro-Guidewire Control in Large Workspaces — arXiv:2609.16354 — arXiv (en), https://arxiv.org/abs/2609.16354 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_9260d8815ebd (Metraipolis archive dc_9260d8815ebd, sha256 ef6b1681eeb941d59a2da4bfb246c14420df3708c2951a834849edcd4c65fdde)
BibTeX
@misc{dc9260d8815ebd,
title = {Electromagnetic Micro-Guidewire Control in Large Workspaces — arXiv:2609.16354},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.16354},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_9260d8815ebd; sha256 ef6b1681eeb941d59a2da4bfb246c14420df3708c2951a834849edcd4c65fdde},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.16354. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Electromagnetic navigation requires sufficient actuation at clinically relevant distances due to limited magnetic volumes and coil currents. We combine real-time pose feedback with constrained convex optimization, dynamic feedback, and repetitive control to achieve energy-efficient micro-guidewire steering inside realistic anatomical models. Experiments with a clinically oriented, three-coil electromagnetic navigation system and a 0.6 mm-diameter tip magnet demonstrate angular tracking with root-mean-square errors below 0.25 degrees at distances up to 55 cm from the coil cover. Nullspace current redistribution maintains accurate tracking under active 45 A coil-current constraints. Compared with conventional field alignment, we demonstrate that pose-dependent torque-based allocation substantially reduces current demand, with the efficiency benefit retained at a pose-feedback rate of 15 Hz. These results demonstrate how real-time state information and optimization can extend electromagnetic guidewire control toward clinically relevant working distances. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-16 in eess.SY). Categorie arXiv: Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2609.16354 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-15T22:15:42.158Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-09-16?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).