Metraipolis › archive › dc_91d0c4804aad

Field laboratory comparison of STANDARD Q Filariasis Antigen Test (QFAT) with Bioline Filariasis Test Strip (FTS) for the detection of Lymphatic Filariasis in… — Europe PMC PMID:39102429

Source
Europe PMC (en)
Original
https://europepmc.org/article/MED/39102429
DOI
10.1371/journal.pntd.0012386
License (as archived)
CC0-1.0
Archived
2026-10-06T16:54:44.956Z
SHA-256 of the archived text
7a73eab17645dfc959342be17f6930e854df9b10c78a56e5e1e44679a8b789cf
Stable URL of this page
https://metraipolis.com/documento/dc_91d0c4804aad

How to cite

Field laboratory comparison of STANDARD Q Filariasis Antigen Test (QFAT) with Bioline Filariasis Test Strip (FTS) for the detection of Lymphatic Filariasis in… — Europe PMC PMID:39102429 — Europe PMC (en), https://europepmc.org/article/MED/39102429 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_91d0c4804aad (Metraipolis archive dc_91d0c4804aad, sha256 7a73eab17645dfc959342be17f6930e854df9b10c78a56e5e1e44679a8b789cf)
BibTeX
@misc{dc91d0c4804aad,
  title = {Field laboratory comparison of STANDARD Q Filariasis Antigen Test (QFAT) with Bioline Filariasis Test Strip (FTS) for the detection of Lymphatic Filariasis in… — Europe PMC PMID:39102429},
  howpublished = {Europe PMC (en)},
  url = {https://europepmc.org/article/MED/39102429},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_91d0c4804aad; sha256 7a73eab17645dfc959342be17f6930e854df9b10c78a56e5e1e44679a8b789cf},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/39102429. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Background: To monitor the progress of lymphatic filariasis (LF) elimination programmes, field surveys to assess filarial antigen (Ag) prevalence require access to reliable, user-friendly rapid diagnostic tests. We aimed to evaluate the performance of the new Q Filariasis Antigen Test (QFAT) with the currently recommended Filariasis Test Strip (FTS) for detecting the Ag of Wuchereria bancrofti, the causative agent of LF, under field laboratory conditions. Methodology/principal findings: During an LF survey in Samoa, 344 finger-prick blood samples were tested using FTS and QFAT. Microfilariae (Mf) status was determined from blood slides prepared from any sample that reported Ag-positive by either Ag-test. Each test was re-read at 1 hour and the next day to determine the stability of results over time. Overall Ag-positivity by FTS was 29.0% and 30.2% by QFAT. Concordance between the two tests was 93.6% (kappa = 0.85). Of the 101 Mf slides available, 39.6% were Mf-positive, and all were Ag-positive by both tests. Darker test line intensities from Ag-positive FTS were found to predict Mf-positivity (compared to same/lighter line intensities). QFAT had significantly higher reported test result changes than FTS, mostly reported the next day, but fewer changes were reported between 10 minutes to 1hour. The field laboratory team preferred QFAT over FTS due to the smaller blood volume required, better usability, and easier readability. Conclusion/significance: QFAT could be a suitable and user-friendly diagnostic alternative for use in the monitoring and surveillance of LF in field surveys based on its similar performance to FTS under field laboratory conditions.

Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera).
Pubblicazione: PLoS neglected tropical diseases, 2024 (prima pubblicazione 2024-08-05).
Identificativi: PMID 39102429 · PMCID PMC11326698 · DOI 10.1371/journal.pntd.0012386.
Descrittori MeSH principali: Wuchereria bancrofti; Elephantiasis, Filarial; Antigens, Helminth.
Pagina: https://europepmc.org/article/MED/39102429 — https://doi.org/10.1371/journal.pntd.0012386. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0.
Letto il 2026-10-06T15:19:26.750Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.