Metraipolis › archive › dc_911e8492072d

Can General-Purpose Generative AI Supply Training Data for Medical Vision Models? A Multimodal Retrospective Study — arXiv:2611.10484

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.10484
License (as archived)
CC0-1.0
Archived
2026-11-10T18:42:32.033Z
SHA-256 of the archived text
b6567a01714890586ceb5010facbf08c8e8a816ce3dec303754dba2e857d18f5
Stable URL of this page
https://metraipolis.com/documento/dc_911e8492072d

How to cite

Can General-Purpose Generative AI Supply Training Data for Medical Vision Models? A Multimodal Retrospective Study — arXiv:2611.10484 — arXiv (en), https://arxiv.org/abs/2611.10484 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_911e8492072d (Metraipolis archive dc_911e8492072d, sha256 b6567a01714890586ceb5010facbf08c8e8a816ce3dec303754dba2e857d18f5)
BibTeX
@misc{dc911e8492072d,
  title = {Can General-Purpose Generative AI Supply Training Data for Medical Vision Models? A Multimodal Retrospective Study — arXiv:2611.10484},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.10484},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_911e8492072d; sha256 b6567a01714890586ceb5010facbf08c8e8a816ce3dec303754dba2e857d18f5},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.10484. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Background: Well-annotated, diverse medical imaging datasets remain a major constraint for vision-based medical AI. We evaluated Nano Banana, a general-purpose image generation and editing model, as a source of synthetic medical images for model training, subgroup augmentation, and model auditing. Methods: In this retrospective study across four imaging modalities, chest radiography, fundus photography, and CT models were trained only on synthetic images and externally validated on real-world data against real-data-trained models. Carotid ultrasound models were trained on a private Human Phenotype Project cohort (aged 40-75 years) with and without synthetic augmentation. Clinicians rated image plausibility. Evaluation used AUROC, AUPR, calibration, and decision curve analysis. Findings: Synthetic-only models achieved AUROCs of 0.877 (95% CI 0.843-0.910) for pneumonia (n=14863), 0.963 (0.948-0.975) for retinal detachment (n=1149), and 0.711 (0.600-0.823) for renal calculus (n=4122), comparable to real-data-trained models, but their calibration and net benefit were not consistently more favorable. With mixed synthetic-real training, a carotid ultrasound model produced an ordinal vascular age index that stratified 633 external subjects into subgroups differing in BMI and glucose (both p<0.01), linking vascular aging to cardiometabolic health. To stress-test shortcut learning, editing a moderate tessellated pattern into fundus photographs reduced the true-class probability for central serous chorioretinopathy from 0.996 to 0.822. Clinician-guided editing raised low-quality CT plausibility from 3.10/5 to 4.30/5. Interpretation: Synthetic data can complement real data in model training, subgroup representation, and model testing via controlled editing, but its clinical value should be assessed with calibration, decision curve analysis, and clinician review, not discrimination alone.

Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.AI, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2611.10484 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-10T18:37:37.590Z dalla pagina https://arxiv.org/list/cs.AI/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).