Metraipolis › archive › dc_908fdae64cb2

Grid-Mode-Aware Model Predictive Control of Hybrid Energy Storage Systems for AI Data Center Power Smoothing — arXiv:2609.04398

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.04398
License (as archived)
CC0-1.0
Archived
2026-10-17T00:40:46.570Z
SHA-256 of the archived text
e11ec0479d133272ef94ddd4e1fa9b670c031c1a22c86dc46c17b0570f2732b0
Stable URL of this page
https://metraipolis.com/documento/dc_908fdae64cb2

How to cite

Grid-Mode-Aware Model Predictive Control of Hybrid Energy Storage Systems for AI Data Center Power Smoothing — arXiv:2609.04398 — arXiv (en), https://arxiv.org/abs/2609.04398 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_908fdae64cb2 (Metraipolis archive dc_908fdae64cb2, sha256 e11ec0479d133272ef94ddd4e1fa9b670c031c1a22c86dc46c17b0570f2732b0)
BibTeX
@misc{dc908fdae64cb2,
  title = {Grid-Mode-Aware Model Predictive Control of Hybrid Energy Storage Systems for AI Data Center Power Smoothing — arXiv:2609.04398},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.04398},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_908fdae64cb2; sha256 e11ec0479d133272ef94ddd4e1fa9b670c031c1a22c86dc46c17b0570f2732b0},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.04398. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

To facilitate the grid-friendly integration of highly variable AI data center loads, this paper proposes a grid-mode-aware model predictive control (G-MPC) framework for managing a hybrid energy storage system (HESS) to smooth grid-side power demand. The framework optimally coordinates a battery energy storage system (BESS) and a supercapacitor (SC) by solving a multi-step optimization problem in a receding-horizon manner. In particular, band-pass filter dynamics are directly embedded in the G-MPC formulation to extract and suppress grid-side power components associated with vulnerable grid oscillatory modes, thus mitigating load-induced grid oscillations. The resulting G-MPC optimization jointly minimizes violations of grid-side power-envelope, ramp-rate, and modal-power requirements and the degradation and power-ramping costs of the BESS and SC, while satisfying power limits, state-of-charge limits, and other operational constraints. To enable real-time implementation, a fix-and-re-optimize algorithm is developed to solve each G-MPC problem efficiently while preventing simultaneous charging and discharging. Extensive simulations demonstrate the effectiveness, flexibility, and computational efficiency of the proposed framework. The results also highlight the importance of explicitly suppressing power components associated with vulnerable grid modes, rather than merely reducing overall load variations, to effectively mitigate grid oscillations.

Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-07 in eess.SY).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2609.04398 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-17T00:12:32.307Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-09-07?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).