Metraipolis › archive › dc_8ff1f667d3bc

MedAstra: ASR-less Speech Retrieval with Diagnostic Grounding for Medical QA — arXiv:2611.01261

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.01261
License (as archived)
CC0-1.0
Archived
2026-11-03T18:22:47.235Z
SHA-256 of the archived text
e87c5f623b5abc1641f50964e40f658b2b375a0a0374c4772a8717662f3ad19b
Stable URL of this page
https://metraipolis.com/documento/dc_8ff1f667d3bc

How to cite

MedAstra: ASR-less Speech Retrieval with Diagnostic Grounding for Medical QA — arXiv:2611.01261 — arXiv (en), https://arxiv.org/abs/2611.01261 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_8ff1f667d3bc (Metraipolis archive dc_8ff1f667d3bc, sha256 e87c5f623b5abc1641f50964e40f658b2b375a0a0374c4772a8717662f3ad19b)
BibTeX
@misc{dc8ff1f667d3bc,
  title = {MedAstra: ASR-less Speech Retrieval with Diagnostic Grounding for Medical QA — arXiv:2611.01261},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.01261},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_8ff1f667d3bc; sha256 e87c5f623b5abc1641f50964e40f658b2b375a0a0374c4772a8717662f3ad19b},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.01261. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Spoken medical question answering can fail when automatic speech recognition (ASR) corrupts a clinically important term before retrieval. We present MedAstra, a framework that maps frozen WavLM speech representations through a lightweight adapter into a frozen E5 text embedding space. This enables a dense retrieval path that accepts a waveform without a query transcript. Retrieved passages and speech-linked textual metadata support answer generation with entity alternatives, diagnostic contrasts, relation heuristics, and bounded retrieval refinement. ASR-less refers to the initial speech retrieval interface; lexical retrieval, string-based entity correction, and the text generator require textual inputs. The deterministic speech embedding does not constitute a calibrated model of acoustic uncertainty. Reported retrieval results reach 87.6 Recall@10 for the speech-only retriever and 90.4 for the hybrid configuration, compared with 81.0 for transcript-first dense retrieval. Medical QA and ablations provide descriptive system comparisons, with input-provenance and evaluation limitations stated explicitly. We distinguish controlled synthetic acoustic tests from real clinical speech, qualify component attribution, and specify the remaining comparisons needed to assess speech-only QA and clinical generalization.

Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.CL, nuovi lavori del giorno).
Categorie arXiv: Computation and Language (cs.CL).
Pagina del lavoro: https://arxiv.org/abs/2611.01261 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-03T18:10:07.916Z dalla pagina https://arxiv.org/list/cs.CL/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).