Metraipolis › archive › dc_8fa14f6fd5e5

Coarse-to-Fine Diffusion with Residual Prior for Low-Dose CT Denoising — arXiv:2611.00016

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.00016
License (as archived)
CC0-1.0
Archived
2026-11-03T11:56:44.231Z
SHA-256 of the archived text
24d66625c9c08f933513004f58a182ae19a07d170032bc49996251c87816c21d
Stable URL of this page
https://metraipolis.com/documento/dc_8fa14f6fd5e5

How to cite

Coarse-to-Fine Diffusion with Residual Prior for Low-Dose CT Denoising — arXiv:2611.00016 — arXiv (en), https://arxiv.org/abs/2611.00016 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_8fa14f6fd5e5 (Metraipolis archive dc_8fa14f6fd5e5, sha256 24d66625c9c08f933513004f58a182ae19a07d170032bc49996251c87816c21d)
BibTeX
@misc{dc8fa14f6fd5e5,
  title = {Coarse-to-Fine Diffusion with Residual Prior for Low-Dose CT Denoising — arXiv:2611.00016},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.00016},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_8fa14f6fd5e5; sha256 24d66625c9c08f933513004f58a182ae19a07d170032bc49996251c87816c21d},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.00016. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Low-dose CT (LDCT) reduces radiation exposure but often introduces severe noise and streak artifacts that obscure subtle anatomical structures. Existing diffusion-based denoising methods commonly rely on implicit assumptions about the noise distribution, which may not hold in practical LDCT scenarios and can degrade denoising performance. To address this limitation, we propose a Residual-Guided Diffusion framework that effectively incorporates an explicit difference prior to inform the diffusion process of noise distribution. The difference prior is computed as the residual between the LDCT image and a coarse clean estimate, constraining diffusion sampling to a plausible residual space. We further adopt a coarse-to-fine strategy in which a pre-trained RED-CNN provides the coarse estimate to anchor global anatomy, and the diffusion model refines the remaining details under the prior guidance. For efficiency, we employ accelerated sampling with 20 steps at inference. Experiments on three representative datasets demonstrate that our approach outperforms existing methods in both quantitative and qualitative performance measures.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv eess.IV, nuovi lavori del giorno).
Categorie arXiv: Image and Video Processing (eess.IV).
Pagina del lavoro: https://arxiv.org/abs/2611.00016 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-03T11:16:07.685Z dalla pagina https://arxiv.org/list/eess.IV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).