Metraipolis › archive › dc_8f7f78e02b60
Preview-Based Relative-Motion Control of an Insertion Tool for Neural-Thread Placement in Pulsating Tissue — arXiv:2608.08860
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.08860
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-19T09:13:06.351Z
- SHA-256 of the archived text
5e8cb7d6d568d13fd557919d6e5824bcb020b1665e8b95259cff64e1475d0ee8- Stable URL of this page
https://metraipolis.com/documento/dc_8f7f78e02b60
How to cite
Preview-Based Relative-Motion Control of an Insertion Tool for Neural-Thread Placement in Pulsating Tissue — arXiv:2608.08860 — arXiv (en), https://arxiv.org/abs/2608.08860 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_8f7f78e02b60 (Metraipolis archive dc_8f7f78e02b60, sha256 5e8cb7d6d568d13fd557919d6e5824bcb020b1665e8b95259cff64e1475d0ee8)
BibTeX
@misc{dc8f7f78e02b60,
title = {Preview-Based Relative-Motion Control of an Insertion Tool for Neural-Thread Placement in Pulsating Tissue — arXiv:2608.08860},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.08860},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_8f7f78e02b60; sha256 5e8cb7d6d568d13fd557919d6e5824bcb020b1665e8b95259cff64e1475d0ee8},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.08860. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Flexible neural electrode threads must be placed at a prescribed depth while the cortical surface moves with cardiac and respiratory pulsation. A controller tracking a fixed point in the laboratory frame cannot distinguish commanded insertion from tissue motion; the error appears as both a depth offset and relative tip--tissue velocity during contact. This paper formulates thread insertion in tissue-relative coordinates: a harmonic observer predicts delayed cortical-surface motion over the control horizon, a constrained MPC regulates the tip relative to that prediction while limiting actuator effort and lateral relative velocity, and an augmented disturbance state removes the steady offset from persistent contact force and model mismatch. In a 1-DOF MuJoCo benchmark, the controller reaches RMS relative-placement errors of 12.0\um\ free-space and 1.9\um\ in contact, versus 18.3/176.8\um\ for delayed-feedback impedance and 286.1/275.5\um\ for laboratory-frame PD -- the lower contact offset costs more peak contact force (3.43 vs.\ 2.00~mN), since it drives to commanded depth rather than yielding to tissue. A 3-DOF extension reduces lateral shear velocity from 1.34 to 0.50~mm/s at 2.1\um\ lateral placement error, and a feasibility-restoring soft-slack formulation keeps the shear constraint solvable under degraded sensing where a matched hard-constraint controller fails. A two-vertex Lyapunov certificate for the finite-horizon gain holds over $-40\%/{+}50\%$ reflected-mass mismatch, and the 1-DOF QP solves in under 0.4~ms at the 95th percentile. These results are a simulation-based control benchmark, not a clinical safety claim: the modeled tip is a rigid contact point, and flexible-thread mechanics, a validated force constraint, biological damage thresholds, and hardware-realistic sensing and timing remain necessary before deployment.
Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-11 in cs.RO).
Categorie arXiv: Systems and Control (eess.SY) ; Human-Computer Interaction (cs.HC); Robotics (cs.RO); Medical Physics (physics.med-ph).
Pagina del lavoro: https://arxiv.org/abs/2608.08860 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-19T09:11:58.825Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-08-11?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).