Metraipolis › archive › dc_8f7a4b172ec7
Rigid monoclonal antibodies improve detection of SARS-CoV-2 nucleocapsid protein — Europe PMC PPR:PPR265621
- Source
- Europe PMC
- Original
- https://europepmc.org/article/PPR/PPR265621
- DOI
- 10.1101/2021.01.13.426597
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-06T09:48:27.519Z
- SHA-256 of the archived text
aa00d8e2e8dd4f44c7183e919e3044d17d75320bef8e6c6607f22d5ce8841d98- Stable URL of this page
https://metraipolis.com/documento/dc_8f7a4b172ec7
How to cite
Rigid monoclonal antibodies improve detection of SARS-CoV-2 nucleocapsid protein — Europe PMC PPR:PPR265621 — Europe PMC, https://europepmc.org/article/PPR/PPR265621 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_8f7a4b172ec7 (Metraipolis archive dc_8f7a4b172ec7, sha256 aa00d8e2e8dd4f44c7183e919e3044d17d75320bef8e6c6607f22d5ce8841d98)
BibTeX
@misc{dc8f7a4b172ec7,
title = {Rigid monoclonal antibodies improve detection of SARS-CoV-2 nucleocapsid protein — Europe PMC PPR:PPR265621},
howpublished = {Europe PMC},
url = {https://europepmc.org/article/PPR/PPR265621},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_8f7a4b172ec7; sha256 aa00d8e2e8dd4f44c7183e919e3044d17d75320bef8e6c6607f22d5ce8841d98},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: Europe PMC, https://europepmc.org/article/PPR/PPR265621. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Monoclonal antibodies (mAbs) are the basis of treatments and diagnostics for pathogens and other biological phenomena. We conducted a structural characterization of mAbs against the N-terminal domain of nucleocapsid protein (NP NTD ) from SARS-CoV-2 using small angle X-ray scattering (SAXS). Our solution-based results distinguished the mAbs’ flexibility and how this flexibility impacts the assembly of multiple mAbs on an antigen. By pairing two mAbs that bind different epitopes on the NP NTD , we show that flexible mAbs form a closed sandwich-like complex. With rigid mAbs, a juxtaposition of the Fabs is prevented, enforcing a linear arrangement of the mAb pair, which facilitates further mAb polymerization. In a modified sandwich ELISA, we show the rigid mAb-pairings with linear polymerization led to increased NP NTD detection sensitivity. These enhancements can expedite the development of more sensitive and selective antigen-detecting point-of-care lateral flow devices (LFA), key for early diagnosis and epidemiological studies of SARS-CoV-2 and other pathogens. Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera). Pubblicazione: bioRxiv, 2021 (prima pubblicazione 2021-01-13). Identificativi: DOI 10.1101/2021.01.13.426597. Pagina: https://europepmc.org/article/PPR/PPR265621 — https://doi.org/10.1101/2021.01.13.426597. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0. Letto il 2026-11-06T09:44:20.783Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.