Metraipolis › archive › dc_8eef387341ee

Goal-Driven Autonomous Optical Experimentation via a Self-Recursive Hardware-Software Harness — arXiv:2611.04481

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.04481
License (as archived)
CC0-1.0
Archived
2026-11-04T21:35:39.020Z
SHA-256 of the archived text
38a7acef7d0e0bacf3e87c59b404d9478a5507788c926f22389a4c282988f82a
Stable URL of this page
https://metraipolis.com/documento/dc_8eef387341ee

How to cite

Goal-Driven Autonomous Optical Experimentation via a Self-Recursive Hardware-Software Harness — arXiv:2611.04481 — arXiv (en), https://arxiv.org/abs/2611.04481 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_8eef387341ee (Metraipolis archive dc_8eef387341ee, sha256 38a7acef7d0e0bacf3e87c59b404d9478a5507788c926f22389a4c282988f82a)
BibTeX
@misc{dc8eef387341ee,
  title = {Goal-Driven Autonomous Optical Experimentation via a Self-Recursive Hardware-Software Harness — arXiv:2611.04481},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.04481},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_8eef387341ee; sha256 38a7acef7d0e0bacf3e87c59b404d9478a5507788c926f22389a4c282988f82a},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.04481. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

We propose goal-driven self-recursive optical research in which agents use physical evidence to revise the hardware, software, models, and protocols used to pursue a scientific goal. The framework can be instantiated with different stimulus systems and measurement devices. We formalize its updates and derive a relation between physical attainability, command access, and model approximation error. We demonstrate the concept in an optical see-through color-matching case study using an iPad, RayNeo X3 glasses, and a TOP 300 probe coupled to a CAS140D spectroradiometer, both from Instrument Systems. A revised glasses application adds USB-controlled RGB holds and frame acknowledgements, keeping model-generated colors displayed during spectral acquisition. The interface passes 12 live control checks. Spectral feedback reduces one target color difference from 19.756 to 1.211 {\Delta}E_76^*; all five targets improve in a separate comparison. These measurements demonstrate the concept in one configuration. The resulting software and protocols remain available for subsequent investigations.

Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.MA, nuovi lavori del giorno).
Categorie arXiv: Artificial Intelligence (cs.AI) ; Multiagent Systems (cs.MA).
Pagina del lavoro: https://arxiv.org/abs/2611.04481 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-04T21:35:34.332Z dalla pagina https://arxiv.org/list/cs.MA/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).