Metraipolis › archive › dc_8dd29cfb0dcf
Air filtration in operating rooms — Wikipedia (en)
- Source
- Wikipedia (en)
- Original
- https://en.wikipedia.org/wiki/Air_filtration_in_operating_rooms
- License (as archived)
- CC-BY-SA-4.0
- Archived
- 2026-11-07T21:56:08.276Z
- SHA-256 of the archived text
50d1a268126a0e1bce57e382b1e1d90f09bf9cf49b936859c28a9fb226cd1c65- Stable URL of this page
https://metraipolis.com/documento/dc_8dd29cfb0dcf
How to cite
Air filtration in operating rooms — Wikipedia (en) — Wikipedia (en), https://en.wikipedia.org/wiki/Air_filtration_in_operating_rooms (CC-BY-SA-4.0); archived copy: https://metraipolis.com/documento/dc_8dd29cfb0dcf (Metraipolis archive dc_8dd29cfb0dcf, sha256 50d1a268126a0e1bce57e382b1e1d90f09bf9cf49b936859c28a9fb226cd1c65)
BibTeX
@misc{dc8dd29cfb0dcf,
title = {Air filtration in operating rooms — Wikipedia (en)},
howpublished = {Wikipedia (en)},
url = {https://en.wikipedia.org/wiki/Air_filtration_in_operating_rooms},
note = {License CC-BY-SA-4.0; archived copy https://metraipolis.com/documento/dc_8dd29cfb0dcf; sha256 50d1a268126a0e1bce57e382b1e1d90f09bf9cf49b936859c28a9fb226cd1c65},
year = {2026}
}Archived text
Reproduced under CC-BY-SA-4.0. Attribution: Wikipedia (en), https://en.wikipedia.org/wiki/Air_filtration_in_operating_rooms. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Air filtration guidelines for operating rooms are determined by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) using a standard known as Minimum Efficiency Reporting Value (MERV). MERV is determined based on the size of particles successfully removed from the air and is used to classify the efficiency of HEPA filters. Ratings range from 1-16 and efficiency increases as the rating increases. ASHRAE groups surgeries into three categories: minor surgical procedures (A); minor or major surgical procedures performed with minor sedation (B); and major surgical procedures performed with general anesthesia or regional block anesthesia (C). Each surgical category is given a minimum MERV rating that it must comply with. Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (deposito sistematico; retro-catalogo: tutte le voci di Wikipedia in inglese, in ordine alfabetico). Fonte: Wikipedia in inglese, voce «Air filtration in operating rooms» — https://en.wikipedia.org/wiki/Air_filtration_in_operating_rooms Wikidata Q96371593 (dati Wikidata in CC0 1.0) — https://www.wikidata.org/wiki/Q96371593 Autori: i contributori di Wikipedia (cronologia: https://en.wikipedia.org/wiki/Air_filtration_in_operating_rooms?action=history). Licenza: Creative Commons Attribuzione-Condividi allo stesso modo 4.0 (CC BY-SA 4.0) — https://creativecommons.org/licenses/by-sa/4.0/. Il riuso richiede attribuzione e stessa licenza. Estratto dell'introduzione non modificato nel contenuto; revisione 1375962362, consultata il 2026-11-07T21:51:55.150Z tramite l'API ufficiale di Wikipedia. Impronta SHA-256 dell'estratto: ddd79569d6dfb51c1d6606020520271170da779e5e210ffba5de2b8dac6875b1