Metraipolis › archive › dc_8da608a9262c

Same path, different: a mechanistic comparison of looped and stacked transformer encoders on 12-lead ECG — arXiv:2609.15498

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.15498
License (as archived)
CC0-1.0
Archived
2026-10-16T00:11:42.923Z
SHA-256 of the archived text
4c35f77633d8d35d7965b41eaa79e9e52da3bfd167a90e6cdeaf95ab11f98b7e
Stable URL of this page
https://metraipolis.com/documento/dc_8da608a9262c

How to cite

Same path, different: a mechanistic comparison of looped and stacked transformer encoders on 12-lead ECG — arXiv:2609.15498 — arXiv (en), https://arxiv.org/abs/2609.15498 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_8da608a9262c (Metraipolis archive dc_8da608a9262c, sha256 4c35f77633d8d35d7965b41eaa79e9e52da3bfd167a90e6cdeaf95ab11f98b7e)
BibTeX
@misc{dc8da608a9262c,
  title = {Same path, different: a mechanistic comparison of looped and stacked transformer encoders on 12-lead ECG — arXiv:2609.15498},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.15498},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_8da608a9262c; sha256 4c35f77633d8d35d7965b41eaa79e9e52da3bfd167a90e6cdeaf95ab11f98b7e},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.15498. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Recurrent Transformers reusing their weights rather than stacking $L$ distinct layers are becoming widely adopted due to their parameter efficiency [1,2,3]. However, the exact representational and dynamical differences between looped and stacked architectures remain uncharacterized. This paper presents a controlled study on the example of bViT model [1] applying one weight-tied block $L$ times. We train two models: bViT and standard ViT [4] on 12-lead electrocardiogram (ECG) classification tasks from the PTB-XL dataset under identical training protocols. Despite an $8.9\times$ parameter reduction, bViT achieves accuracy parity with ViT. Geometric similarity metrics demonstrate that both architectures construct comparable latent representations in an equivalent canonical order. Crucially, their dynamics differ: bViT exhibits smaller step sizes and inter-patient sensitivity, as well as near-neutral behavior away from the data manifold, whereas ViT exhibits collapsing dimensionality of representations and out-of-distribution feature expansion.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-15 in cs.LG).
Categorie arXiv: Machine Learning (cs.LG) ; Dynamical Systems (math.DS).
Pagina del lavoro: https://arxiv.org/abs/2609.15498 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-15T23:54:14.767Z dalla pagina https://arxiv.org/catchup/cs.LG/2026-09-15?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).