Metraipolis › archive › dc_8d07195efc4f
A comparative study on the accuracy & repeatability of mobile robotic platforms for the delivery of precision NDE measurement — arXiv:2609.03794
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.03794
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T02:57:33.506Z
- SHA-256 of the archived text
1dd583bded90dbb6168bd155f2b894c9d72972eb2e053011a404abf63068c6bf- Stable URL of this page
https://metraipolis.com/documento/dc_8d07195efc4f
How to cite
A comparative study on the accuracy & repeatability of mobile robotic platforms for the delivery of precision NDE measurement — arXiv:2609.03794 — arXiv (en), https://arxiv.org/abs/2609.03794 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_8d07195efc4f (Metraipolis archive dc_8d07195efc4f, sha256 1dd583bded90dbb6168bd155f2b894c9d72972eb2e053011a404abf63068c6bf)
BibTeX
@misc{dc8d07195efc4f,
title = {A comparative study on the accuracy & repeatability of mobile robotic platforms for the delivery of precision NDE measurement — arXiv:2609.03794},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.03794},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_8d07195efc4f; sha256 1dd583bded90dbb6168bd155f2b894c9d72972eb2e053011a404abf63068c6bf},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.03794. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Mobile robotic platforms offer a flexible alternative to fixed manipulators for non-destructive evaluation (NDE) of large aerospace structures, but their base-positioning accuracy and how that accuracy should inform deployment have not been assessed under a common, externally referenced protocol. This work presents a laser tracker-based evaluation workflow (ground truth approximately 6 micrometers) that measures the static and segmented trajectory positioning accuracy of five commercial mobile platforms (KUKA KMP-1500, KUKA KMR, MiR250, Boston Dynamics Spot, Clearpath Husky) under a common protocol. A coupled multi-corner calibration recovers the laser-to-robot transformation and reflector offsets; ordinary least squares over all poses is used, with robust estimation retained only as a blunder check. Static positioning accuracy ranged from a median of 8.2 mm (KMP-1500) to 63.5 mm (Spot), with the wheel-odometry-only Husky uncalibratable. Dynamic path following was characterised by cross-track error; the component was insensitive to temporal alignment, which ranged from 6.9 mm (KMP-1500) to 112.1 mm (Spot). Both accuracy and calibratability tracked localisation capability, from the newest LiDAR SLAM platform to map-free visual odometry. No configuration meets the 0.2 to 1.0 mm aerospace NDE tolerance from the base alone; the results are framed as a design input that sizes the supplementary sensing each platform requires: roughly one order of magnitude for the best platform and nearly two for the worst, providing a reproducible basis for platform selection rather than a feasibility claim. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-04 in cs.RO). Categorie arXiv: Robotics (cs.RO). Pagina del lavoro: https://arxiv.org/abs/2609.03794 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-17T02:33:25.405Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-09-04?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).