Metraipolis › archive › dc_8c6575263ec2
Evaluating the Safety of Deep Learning-Based Brain MRI Reconstruction — arXiv:2608.28714
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.28714
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T09:59:56.022Z
- SHA-256 of the archived text
71b7b0b1efa73e36ca9d0cfa59303eb1806dfcea8107340f80b3a037f72afbd0- Stable URL of this page
https://metraipolis.com/documento/dc_8c6575263ec2
How to cite
Evaluating the Safety of Deep Learning-Based Brain MRI Reconstruction — arXiv:2608.28714 — arXiv (en), https://arxiv.org/abs/2608.28714 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_8c6575263ec2 (Metraipolis archive dc_8c6575263ec2, sha256 71b7b0b1efa73e36ca9d0cfa59303eb1806dfcea8107340f80b3a037f72afbd0)
BibTeX
@misc{dc8c6575263ec2,
title = {Evaluating the Safety of Deep Learning-Based Brain MRI Reconstruction — arXiv:2608.28714},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.28714},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_8c6575263ec2; sha256 71b7b0b1efa73e36ca9d0cfa59303eb1806dfcea8107340f80b3a037f72afbd0},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.28714. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Objective: Deep learning accelerates brain MRI four- to tenfold, but models can erase lesions or synthesize false tissue - failures pixel-averaged metrics like PSNR and SSIM miss. We review whether current evaluation practices detect this blind spot. Methods: Following PRISMA 2020, we searched seven databases without date limits, including 263 studies (1995-2026), appraised them using QUADAS-2 and matched instruments, and synthesized narratively. Categories were derived from titles, abstracts, and controlled vocabulary; reported prevalence figures represent floors. Duplicate screening achieved high agreement (Fleiss kappa = 0.877), as did appraisal (0.788; 0.390 where observable). Extraction is unaudited. Results: Only 18 of 263 studies (6.8%) recorded both a fidelity metric and reader assessment on identical data, leaving the central surrogate unmeasured. Reader studies mostly measured inter-reader agreement, which was weak: fastMRI 2020 concordance reached 0.457 and 0.386 (Kendall W), improving only where SSIM diverged. Erasing a 100 mm3 lacunar infarct shifts global PSNR by 0.03 dB under the stated error model. As the corpus grew fivefold, reader assessments dropped from 32% to 18%, recovering to 21%. Generative models - most associated with hallucination (39%) - were among the least reader-evaluated (11.3%), while self-supervised models reached 47% with zero reader evaluation. Only 5% released code and ran reader studies; none evaluated a model observer; no named dataset covered acute stroke or hemorrhage. Conclusions: On these floors, current evaluation practices cannot certify diagnostic safety. We derive five requirements safety-oriented evaluations must meet. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-01 in cs.CV). Categorie arXiv: Image and Video Processing (eess.IV) ; Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2608.28714 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-17T09:28:48.243Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).