Metraipolis › archive › dc_8ac8fcd58aca

A comparative study on the lipid layer thickness analysis of medical staff before and after work — Europe PMC PMID:39494281

Source
Europe PMC (en)
Original
https://europepmc.org/article/MED/39494281
DOI
10.7717/peerj.18258
License (as archived)
CC0-1.0
Archived
2026-10-06T15:12:57.210Z
SHA-256 of the archived text
53cebeac94b4bb996016f59583dd0a8610bc4b0dafc9935f31ed6e2ac0252d55
Stable URL of this page
https://metraipolis.com/documento/dc_8ac8fcd58aca

How to cite

A comparative study on the lipid layer thickness analysis of medical staff before and after work — Europe PMC PMID:39494281 — Europe PMC (en), https://europepmc.org/article/MED/39494281 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_8ac8fcd58aca (Metraipolis archive dc_8ac8fcd58aca, sha256 53cebeac94b4bb996016f59583dd0a8610bc4b0dafc9935f31ed6e2ac0252d55)
BibTeX
@misc{dc8ac8fcd58aca,
  title = {A comparative study on the lipid layer thickness analysis of medical staff before and after work — Europe PMC PMID:39494281},
  howpublished = {Europe PMC (en)},
  url = {https://europepmc.org/article/MED/39494281},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_8ac8fcd58aca; sha256 53cebeac94b4bb996016f59583dd0a8610bc4b0dafc9935f31ed6e2ac0252d55},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/39494281. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Background & aims: To study the change of the lipid layer thickness analysis in medical staff (MS) before and after work, and to explore the significance of measuring lipid layer thickness (LLT) respectively in four quadrants. Methods: Ocular Surface Disease Index (OSDI) questionnaire and video display terminal using time for 55 MS were collected (the informed consent was obtained from all patients). Noninvasive tear break-up time, LLT, tear meniscus height (TMH), meibomian glands (MG) dropout, and blink pattern before and after work (worked for more than 4 h) of 110 eyes were measured by Gaush iDea Ocular surface analyzer. Lid margin abnormalities were evaluated by the slit-lamp microscopy. Results: The average OSDI score of 55 MS was 25.68 ± 14.91. The average LLT of 110 eyes after work (65.12 ± 3.63 nm) was significantly reduced compared to before work (66.54 ± 4.16 nm), p p p p p p = 0.002). There was a significant correlation between the LLT in the inferior quadrant and the VDTt (r = -0.173, p = 0.01). The LLT of inferior quadrant were positively related to the TMH (r = 0.149, p = 0.027) and negatively related to MG dropout in lower lid (r = -0.162, p = 0.017). Conclusion: The LLT significantly decreases after work in MS. The distribution of the lipid layer on the ocular surface is uneven. It is unreasonable for current detection instruments to measure the inferior quadrant LLT alone to represent average LLT.

Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera).
Pubblicazione: PeerJ, 2024 (prima pubblicazione 2024-10-31).
Identificativi: PMID 39494281 · PMCID PMC11531743 · DOI 10.7717/peerj.18258.
Parole chiave degli autori: Medical Staff; Dry Eye Disease; Video Display Terminal; Lipid Layer Thickness; Gaush Idea Ocular Surface Analyzer.
Descrittori MeSH principali: Tears.
Pagina: https://europepmc.org/article/MED/39494281 — https://doi.org/10.7717/peerj.18258. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0.
Letto il 2026-10-06T15:11:36.266Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.