Metraipolis › archive › dc_8aab4b892f96

DiffStent: Surrogate Adjoint Differentiation for Stent Deployment in Anisotropic Arteries — arXiv:2611.00014

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.00014
License (as archived)
CC0-1.0
Archived
2026-11-03T18:48:47.115Z
SHA-256 of the archived text
97e3c81fffe29f5b7016eb6a7270371e751e779dad3586748443113392af8d94
Stable URL of this page
https://metraipolis.com/documento/dc_8aab4b892f96

How to cite

DiffStent: Surrogate Adjoint Differentiation for Stent Deployment in Anisotropic Arteries — arXiv:2611.00014 — arXiv (en), https://arxiv.org/abs/2611.00014 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_8aab4b892f96 (Metraipolis archive dc_8aab4b892f96, sha256 97e3c81fffe29f5b7016eb6a7270371e751e779dad3586748443113392af8d94)
BibTeX
@misc{dc8aab4b892f96,
  title = {DiffStent: Surrogate Adjoint Differentiation for Stent Deployment in Anisotropic Arteries — arXiv:2611.00014},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.00014},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_8aab4b892f96; sha256 97e3c81fffe29f5b7016eb6a7270371e751e779dad3586748443113392af8d94},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.00014. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

We present DiffStent, a differentiable finite element framework for simulating arterial deformation during in silico stent deployment, where nearly incompressible, anisotropic vessel walls undergo large deformation and frictional contact with the stent. DiffStent combines the fiber-reinforced Holzapfel-Gasser-Ogden constitutive model with an implicit discrete adjoint that differentiates the converged mechanical equilibrium without unrolling the nonlinear solver, thus reducing the memory cost by three orders of magnitude. We identify three mechanisms that can lead to inaccurate, unstable, or uninformative gradients: nonsmooth switching, state mismatch, and gradient cancellation. To address these, we apply a contact surrogate in the backward pass while retaining the original physical model in the forward pass. We show superior gradient accuracy of our method over AutoDiff and finite differencing across constitutive benchmarks, idealized stented vessels, and patient-specific calcified coronary anatomies, and use the resulting sensitivities to quantify how tissue properties and calcification patterns govern lumen expansion and arterial wall stress. Finally, we demonstrate that DiffStent enables gradient-based system identification from retrospective clinical images of atherosclerotic coronary anatomy. Together, these results establish a practical approach for differentiating through nonlinear biomechanical simulations with stiff constitutive laws and nonsmooth contact, enabling patient-specific parameter inference and optimization in computational cardiovascular mechanics.

Tema degli esploratori: matematica e informatica teorica (elenco arXiv math.NA, nuovi lavori del giorno).
Categorie arXiv: Medical Physics (physics.med-ph) ; Computational Engineering, Finance, and Science (cs.CE); Numerical Analysis (math.NA).
Pagina del lavoro: https://arxiv.org/abs/2611.00014 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-03T18:15:22.849Z dalla pagina https://arxiv.org/list/math.NA/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).