Metraipolis › archive › dc_891da4cb93db

Benchmarking Intra-Patient 3D Deformable Multimodal Image Registration — arXiv:2609.15669

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.15669
License (as archived)
CC0-1.0
Archived
2026-10-15T22:53:59.939Z
SHA-256 of the archived text
569139f43a57796e16af6e6fdc06c913ef1e92bd799ddf956a54b997c1ccbb2c
Stable URL of this page
https://metraipolis.com/documento/dc_891da4cb93db

How to cite

Benchmarking Intra-Patient 3D Deformable Multimodal Image Registration — arXiv:2609.15669 — arXiv (en), https://arxiv.org/abs/2609.15669 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_891da4cb93db (Metraipolis archive dc_891da4cb93db, sha256 569139f43a57796e16af6e6fdc06c913ef1e92bd799ddf956a54b997c1ccbb2c)
BibTeX
@misc{dc891da4cb93db,
  title = {Benchmarking Intra-Patient 3D Deformable Multimodal Image Registration — arXiv:2609.15669},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.15669},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_891da4cb93db; sha256 569139f43a57796e16af6e6fdc06c913ef1e92bd799ddf956a54b997c1ccbb2c},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.15669. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Multimodal image registration is a key component of many clinical workflows, yet it remains challenging because corresponding anatomical structures often exhibit substantially different image intensities across modalities. In this work, we present a comprehensive benchmark of intra-patient 3D multimodal deformable registration methods across three datasets covering different anatomical regions and difficulty levels, including both synthetic deformation recovery and real clinical scenarios. We evaluate classical optimization-based approaches and modern learning-based methods, including recent deep learning and foundation models, using complementary metrics: Average Dice similarity coefficient (DSC), average 95th-percentile Hausdorff distance (HD95), and a modality-independent structural similarity measure based on the MIND self-similarity context (MIND-SSC). Results show high variability across datasets, with learning-based methods demonstrating superior performance on large synthetic benchmarks, while only limited improvements are observed in real pelvic registration. A key finding of this study is the consistent disagreement between geometric metrics (DSC, HD95) and image-based similarity metrics (MIND-SSC), highlighting that improved overlap does not necessarily imply better global multimodal correspondence. Furthermore, anatomy-guided approaches achieve the highest overlap scores but exhibit degraded performance outside of segmented regions, revealing a trade-off between label-driven alignment and global structural coherence. Overall, our results indicate that no current method achieves robust performance across anatomies and modalities. We demonstrate that intra-patient 3D multimodal registration requires multi-criteria evaluation, including deformation-based metrics, and remains an open problem.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-15 in cs.AI).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2609.15669 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-15T22:29:03.909Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-15?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).