Metraipolis › archive › dc_88e61ee6e586

CMCNet: Aligning Ultrasound Image Embeddings with Textual TI-RADS Representations for Fine-Grained Thyroid Classification — arXiv:2608.13939

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.13939
License (as archived)
CC0-1.0
Archived
2026-10-19T02:21:14.017Z
SHA-256 of the archived text
f656db36d92998b20a2cf525c931894972f702982b94dafb88603df423b630c1
Stable URL of this page
https://metraipolis.com/documento/dc_88e61ee6e586

How to cite

CMCNet: Aligning Ultrasound Image Embeddings with Textual TI-RADS Representations for Fine-Grained Thyroid Classification — arXiv:2608.13939 — arXiv (en), https://arxiv.org/abs/2608.13939 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_88e61ee6e586 (Metraipolis archive dc_88e61ee6e586, sha256 f656db36d92998b20a2cf525c931894972f702982b94dafb88603df423b630c1)
BibTeX
@misc{dc88e61ee6e586,
  title = {CMCNet: Aligning Ultrasound Image Embeddings with Textual TI-RADS Representations for Fine-Grained Thyroid Classification — arXiv:2608.13939},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.13939},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_88e61ee6e586; sha256 f656db36d92998b20a2cf525c931894972f702982b94dafb88603df423b630c1},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.13939. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Ultrasound is the primary imaging modality for assessing thyroid nodules, and the ACR TI-RADS framework standardizes diagnosis through five ultrasound feature categories that are aggregated into five risk levels (TR1-TR5). Although widely adopted in clinical practice, most deep learning approaches focus on binary malignancy classification, while multi-class prediction and explicit utilization of feature-level supervision remain underexplored, largely due to limited annotated data. In this study, we introduce the STN dataset of 600 thyroid nodules with paired transverse and longitudinal ultrasound images, bounding box annotations, and complete labels for all five TI-RADS feature categories. Following the clinical decision process, we investigate how structured feature information can guide representation learning during training while requiring only images at inference. We demonstrate that text embeddings derived from standardized feature descriptions form a stable surrogate representation for TI-RADS risk levels. Based on this observation, we propose CMCNet, which aligns image embeddings to fixed textual embeddings via a Center-Margin Contrastive Loss that simultaneously promotes intra-class compactness and inter-class separation. Experimental results show that this embedding alignment strategy is more data-efficient and robust than direct multitask learning, and consistently outperforms InfoNCE, center loss, a strong multitask baseline, and a VQA-style multimodal model, particularly in imbalanced settings. The dataset is freely available at doi: https://doi.org/10.5281/zenodo.19125693 and the source code is available at: this https URL .

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-08-17 in cs.AI).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2608.13939 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-19T02:02:02.886Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-08-17?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).